Cold-formed structural members are being used more widely in routine structural design as the world steel industry moves from the production of hot-rolled section and plate to coil and strip, often with galvanized and/or painted coatings. Steel in this form is more easily delivered from the steel mill to the manufacturing plant where it is usually cold-rolled into open and closed section members. In the present experimental study, the use of packing plate at the joints in cold-formed channel sections may increase the load carrying capacity and also reduce the buckling of unconnected cold form channel steel plate at joints. The present study focuses on examining the experimental investigation to use mild steel as a packing plate with cold-formed channel sections by bolted connection at the joints and the connection subjected to axial tension. Series of tests are carried out with increase in the thickness of packing plate and results are observed and analyzed. Total Twelve experimental tests have been carried out on cold-formed channel tension members fastened with single as well as three numbers of bolts at the connection and from the observations the strength of the joint is increased by increasing the various thicknesses of packing plates and also the buckling of unconnected leg of channel specimen is reduced. It is analyzed by plotting the entire load versus elongation path, so that the behavior of the connection is examined.
机译:随着世界钢铁工业从热轧型材和薄板的生产转向卷材和带材(通常带有镀锌和/或喷漆),冷弯结构件在常规结构设计中的使用越来越广泛。这种形式的钢更容易从钢厂输送到制造厂,在那里通常将其冷轧成开放式和封闭式截面构件。在本实验研究中,在冷弯槽型截面的接缝处使用填料板可增加承载能力,并减少未连接冷弯型槽形钢板在接缝处的屈曲。本研究的重点是通过在接头处承受螺栓连接和承受轴向拉力的方式,将低碳钢用作具有冷弯通道截面的填料板的实验研究。随着填充板厚度的增加,进行了一系列测试,并观察和分析了结果。在连接处用单个螺栓和三个螺栓固定的冷弯通道张紧构件上进行了总共十二项实验测试,从观察结果看,接头的强度通过增加填料板的各种厚度而增加。减少了通道样本未连接支腿的屈曲。通过绘制整个载荷与伸长路径的关系图进行分析,从而检查连接的行为。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号