Effect of fluidics on corneal endothelial cell density, central corneal thickness, and central macular thickness after phacoemulsification with torsional ultrasound

机译:超声对超声超声乳化白内障术中流控剂对角膜内皮细胞密度,中央角膜厚度和中央黄斑厚度的影响

获取原文
           

摘要

Aim: To study the relative effects of high and low fluidic parameters on endothelial cell density (ECD), central corneal thickness (CCT), and central macular thickness (CMT) after phacoemulsification with torsional ultrasound. Settings and Design: Prospective, randomized clinical trial based on a tertiary eye hospital. Subjects and Methods: The study included 65 patients in each group. Patients were randomized to either the high or the low flow group using a computerized random number table. The study was patient and examiner masked. All patients underwent phacoemulsification with torsional ultrasound. Visual acuity, ECD, CCT, and CMT were measured for all patients preoperatively at 2 weeks and 6 weeks postoperatively. Statistical Analysis Used: The Shapiro–Wilks test was used to assess the normality of the data. Mann–Whitney U-test with the P value set at 0.05 was used to compare the two groups. Results: Cumulative dissipated energy was significantly higher in the low flow group (16.44 ± 9.07 vs. 11.74 ± 6.68; P = 0.002). No statistically significant difference was noted between the two groups in the ECD, CCT, CMT, or corrected distance visual acuity at the end of 6 weeks. Conclusions: No significant difference was noted in the postoperative outcome between high and low flow groups. Parameters can be modified to suit the surgeon's preference, as both high and low flow parameters were found to have comparable postoperative outcomes.
机译:目的:研究扭转超声超声乳化术后高和低流体参数对内皮细胞密度(ECD),中央角膜厚度(CCT)和中央黄斑厚度(CMT)的相对影响。设置和设计:基于三级眼科医院的前瞻性随机临床试验。受试者和方法:该研究包括每组65名患者。使用计算机随机数表将患者随机分为高流量组或低流量组。这项研究是耐心的,检查者被掩盖了。所有患者均接受扭转超声乳化术。术前2周和6周对所有患者的视力,ECD,CCT和CMT进行了测量。使用的统计分析:使用Shapiro-Wilks检验评估数据的正态性。 P值设为0.05的Mann-Whitney U检验用于比较两组。结果:低流量组的累积耗散能量明显更高(分别为16.44±9.07和11.74±6.68; P = 0.002)。在6周结束时,ECD,CCT,CMT或校正的远视力在两组之间均未发现统计学上的显着差异。结论:高流量组和低流量组之间的术后预后没有显着差异。可以修改参数以适合外科医生的喜好,因为发现高流量参数和低流量参数都具有可比的术后结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号