Purpose: To study the technical feasibility of tracheobronchial stenting via transnasal route under bronchoscopy and fluoroscopic guidance in severe malignant airway strictures using self-expandable nitinol stents. Materials and Methods: We describe three patients with malignant airway strictures, treated entirely via transnasal route under local anesthesia using bronchoscopic and fluoroscopic guidance. Nasal route allowed convenient access to the airway for the bronchoscope across the stricture and a guidewire was introduced through its working channel. The 18F tracheal stent and the 6F bronchial stent assembly could be easily introduced and deployed under bronchoscopic (reintroduced through the other nostril) and fluoroscopic guidance. Results: We achieved technical success in all the three patients with immediate relief of dyspnea. Conclusion: Transnasal airway stenting with self-expandable nitinol stent using bronchoscopic and fluoroscopic guidance under local anesthesia is a safe and effective method with minimal patient discomfort.
机译:目的:研究在气管支气管镜和荧光镜引导下经鼻途径气管支气管支架置入严重可恶性气道狭窄的自膨胀镍钛合金支架的技术可行性。材料和方法:我们描述了3例恶性气道狭窄患者,在支气管镜和荧光镜引导下在局部麻醉下完全通过鼻腔途径治疗。鼻部路径允许支气管镜方便地穿过狭窄通道进入气道,并通过其工作通道引入了导丝。 18F气管支架和6F支气管支架组件可以很容易地在支气管镜下(通过另一个鼻孔重新引入)和荧光镜引导下引入和部署。结果:我们在三例呼吸困难立即缓解的患者中均取得了技术成功。结论:在局部麻醉下,在支气管镜和荧光镜引导下,经鼻道气管支架置入自膨胀镍钛合金支架是一种安全有效的方法,可将患者的不适感降至最低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号