Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

机译:使用几种曝光参数对CBCT扫描中的根部填充材料中的图像伪影进行定量评估

获取原文
           

摘要

Purpose To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Materials and Methods Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P Results There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines ( P .05). Conclusion Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.
机译:目的为了量化使用不同曝光参数获取的锥束计算机断层扫描(CBCT)图像中来自不同根填充材料的伪影。材料和方法使用8种不同的暴露方案,使用3种不同的填充材料对15根单根牙齿进行扫描,以一次无对照组为对照组。伪影量化是由训练有素的观察员进行的,该观察员使用ImageJ在感兴趣的固定区域中对所有获取的图像的中心轴向切片进行了测量。确定了高密度伪影,低密度伪影和剩余牙齿面积,并计算了高密度和低密度伪影,剩余牙齿面积以及受伪影影响的牙齿面积的百分比。 2位观察者使用以下分数对伪像进行了定性分析:低密度晕圈,低密度线和高密度线的缺失(0),中等存在(1)和高存在(2)。双向ANOVA和事后Tukey检验用于定量和定性伪像分析。 Dunnet检验也用于定性分析。显着性水平设置为P。结果在定量或定性分析中,暴露参数之间无显着相互作用。在所有定量分析中,观察到的填充材料之间存在显着差异。在定性分析中,所有材料在低密度线和高密度线方面均与对照组不同(P .05)。结论不同的曝光参数不会影响CBCT图像中的伪影的客观或主观观察。但是,用于牙髓修复的填充材料确实影响了两种评估。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号