Background: Various mechanical modifications in the collar region of endosseous implants is a challenge for better performance and osseointegration. Here is a comparative evaluation being carried out to find out the effect of the machined collar (MC) and Laser-Lok (LL)-modified titanium implants on the success of implants being commonly advocated in partially edentulous among serving personnel and their families. Materials and Methods: Twenty-four patients with appropriate inclusion and exclusion criteria were selected for placement of Biohorizons MC and LL implants in 12 cases each. Aseptic surgical procedure was followed for implant surgery, and clinical parameters such as clinical attachment loss, pocket depth (PD), bleeding on probing, and plaque index (PI), mobility parameters estimated by Periotest value, and radiographic assessment of crestal bone loss (CBL) at interval of 6 months and 1 year were recorded and compared by statistical analysis. Results: Intragroup comparison at 6 and 12 months period for all the parameters were nonsignificant except CBL in Group A (CBL-MC) with 12 cases shows a mean of 0.917 and 1.500, respectively, standard deviation difference = 0.477 (significant) with P Conclusion: The presence of LASER textured with microgrooves on the collar of the implants did not increase the PI and sulcular bleeding index. The probing PD was much less as observed in the group of LASER-treated implants in comparison with that of MC group. LL implant had an edge over MC proving success of the laser treatment on collars of implants.
机译:背景:在骨内植入物的颈圈区域进行各种机械改造是提高性能和骨整合的挑战。这里进行了一项比较评估,以发现机加工颈圈(MC)和Laser-Lok(LL)改性的钛植入物对在职人员及其家人普遍缺牙的普遍成功的植入物的效果。材料和方法:选择24例具有适当入选和排除标准的患者,分别放置12例Biohorizo​​ns MC和LL植入物。植入物手术采用无菌外科手术程序进行,临床参数包括临床附着丧失,囊袋深度(PD),探查出血和斑块指数(PI),通过Periotest值估算的活动性参数以及对骨损失的放射学评估(记录间隔6个月和1年的CBL),并通过统计分析进行比较。结果:除A组的CBL(CBL-MC)以外,所有参数在6和12个月时的组内比较均无统计学意义,其中12例的平均值分别为0.917和1.500,P的标准差= 0.477(显着) :在植入物的衣领上存在带有微沟槽的LASER纹理并没有增加PI和沟出血指数。与MC组相比,激光治疗植入物组的探测PD值要低得多。 LL植入物比MC具有优势,证明了在植入物的颈圈上进行激光治疗的成功。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号