首页> 外文期刊>Arquivos Brasileiros de Oftalmologia >Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera
【24h】

Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera

机译:年龄与超高速(UHS)Scheimpflug相机集成的非接触眼压计对角膜变形的影响

获取原文
获取外文期刊封面目录资料

摘要

PURPOSE: To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. METHODS: Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy eyes. The Scheimpflug images were taken with an ultra-high-speed camera during each measurement by the corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachy apex, intraocular pressure, 1st A time, highest concavity-time, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the corvis ST were correlated with age. The Kolmogorov-Smirnov test was applied, and Spearman's correlation test was utilized to evaluate the parameters measured by the Corvis ST and age. RESULTS: Mean patient age was 27.50 ± 6.30 years. The highest concavity-time was the only studied parameter statistically significantly correlated to age (i.e., p=0.04, rs=0.18). All other corvis parameters were not correlated to age. This included DA (p=0.319), intraocular pressure (p=0.854), pachy apex (p=0.066), 1st A time (p=0.959), 2nd A time (p=0.561), 1st Length (0.552), 2nd Length (p=0.697), Wing-Dist (p=0.769), curvature radius HC (p=0.145), curvature radius normal (p=0.513), Vin (p=0.980) and Vout (p=0.592). CONCLUSIONS: In healthy eyes, age and pressure or biomechanics as derived from the Corvis ST parameters were not associated with exception to highest concavity-time, i.e., the time from starting until the highest concavity is reached.
机译:目的:将非接触眼压计与超高速(UHS)Scheimpflug相机(Oculus Corvis ST,Scheimpflug Technology; Wetzlar,德国)集成的角膜变形参数与年轻患者正常眼睛的年龄相关联。方法:观察性回顾性研究涉及从研究参与者中随机选择的一只眼睛,共89只健康眼睛。在每次测量期间,Corvis ST用超高速相机拍摄了Scheimpflug图像。变形幅度(DA)和其他参数(例如,顶尖,眼压,第1次A时间,最高凹度时间,第2次A时间,第1次A长度,第2次A长度,翼长,曲率半径,最大凹度,曲率半径) Corvis ST测得的正常(Vin,Vout)与年龄相关。应用Kolmogorov-Smirnov检验,并使用Spearman相关检验评估Corvis ST和年龄所测得的参数。结果:平均患者年龄为27.50±6.30岁。最高凹度时间是唯一与年龄显着相关的研究参数(即p = 0.04,rs = 0.18)。所有其他corvis参数均与年龄无关。其中包括DA(p = 0.319),眼压(p = 0.854),上颚尖(p = 0.066),第一次(p = 0.959),第二次(p = 0.561),第一次长度(0.552),第二次长度(p = 0.697),机翼距离(p = 0.769),曲率半径HC(p = 0.145),曲率半径法线(p = 0.513),Vin(p = 0.980)和Vout(p = 0.592)。结论:在健康的眼睛中,从Corvis ST参数得出的年龄和压力或生物力学与最高凹度时间(即从开始到达到最高凹度的时间)无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号