Background: In health-care services, when bare upper arm blood pressure (BP) measurement is impractical, the forearm may be used as a surrogate for traditional upper arm BP. Objective: This exploratory study aimed to determine the significant difference and correlation between the upper versus forearm BP measurements among low-risk prenatal women. SMaterials and Methods: A total of 156 low-risk prenatal women in the third trimester of pregnancy attending antenatal clinics at Municipal Maternity Corporation Hospitals, Bengaluru, were recruited by purposive sampling. Upper and forearm noninvasive BP (NIBP) measurements obtained by mercury sphygmomanometer, thrice at an interval of 15 min were averaged. The main outcome measures were the significant difference and correlation between the upper arm and forearm BP measurements. Results: The mean systolic BP (SBP) (117.14 ± 3.041 mmHg) and diastolic BP (DBP) (69.31 ± 8.461 mmHg) in the forearm was significantly higher than the upper arm SBP (111.72 ± 5.53; P = 0.002) and DBP (61.46 ± 6.014 mmHg; P = 0.016). The mean difference in SBP between upper and forearm was 5.42 ± 2.016 mmHg and in DBP 7.85 ± 3.204 mmHg. Upper versus forearm BP measurements had revealed a significant positive linear correlation in SBP (r = 0.849; P = 0.013) and DBP (r = 0.816; P = 0.021) by Pearson product-moment correlation coefficient. Clinically 94 (72.31%) had a significant BP measurements difference in forearm versus upper arm by approximately 6–10 mmHg. None of the maternal characteristics were independent predictors for the mean difference in SBP and DBP measurement. Conclusion: Forearm NIBP measurements are higher than the BP obtained at the upper arm location. This must be taken into consideration whenever the forearm is used as an alternative site for the upper arm BP.
机译:背景:在医疗保健服务中,如果无法测量裸露的上臂血压(BP),则前臂可替代传统上臂BP。目的:这项探索性研究旨在确定低危产前妇女的上血压与前臂血压之间的显着差异和相关性。方法和方法:通过有目的地抽样,总共招募了156名处于妊娠晚期的低风险产前妇女,他们在班加罗尔市妇产公司医院的产前诊所就诊。平均水银血压计获得的上,前臂无创血压(NIBP)测量值,每15分钟间隔三次。主要结局指标是上臂和前臂血压测量值之间的显着差异和相关性。结果:前臂的平均收缩压(SBP)(117.14±3.041 mmHg)和舒张压(DBP)(69.31±8.461 mmHg)显着高于上臂SBP(111.72±5.53; P = 0.002)和DBP( 61.46±6.014 mmHg; P = 0.016)。上臂和前臂之间的SBP平均差为5.42±2.016 mmHg,而DBP为7.85±3.204 mmHg。根据皮尔逊乘积矩相关系数,上臂和前臂的BP测量显示SBP(r = 0.849; P = 0.013)和DBP(r = 0.816; P = 0.021)的显着正线性相关。临床上94名(72.31%)的前臂与上臂的BP测量值有显着差异,约为6-10 mmHg。孕产妇特征均不是SBP和DBP测量平均值差异的独立预测因子。结论:前臂NIBP测量值高于在上臂位置获得的BP。每当将前臂用作上臂BP的替代部位时,都必须考虑到这一点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号