A sensitive and selective kinetic-spectrophotometric method is proposed for the determination of µg mL-1 amounts of Cu2+ based on its catalytic effect on the oxidation of L-ascorbic acid by Methylene Blue in a strongly acidic medium. The reaction is monitored spectrophotometrically by measuring the decrease in color intensity of Methylene Blue at 665 nm. The analysis of Cu2+ ion is performed by a fixed-time method. At a given time of 2 min at pH 2.20 and 32°C, the detection limit is 10 ng mL-1 and the relative standard deviation for 0.4 µg mL-1 Cu2+ is 3.60% (n = 6). The method is free from most of the interferences and the effect of diverse ions on the determination of Cu2+ is also reported. The proposed method is virtually specific to copper and has been satisfactorily applied to its determination in electric copper wire samples and pharmaceutical products. Results were also verified by the atomic absorption spectrometry technique (AAS).
机译:基于强酸性介质中亚甲蓝对L-抗坏血酸氧化的催化作用,提出了一种灵敏的选择性动力学分光光度法测定μgmL-1量的Cu2 +。通过分光光度法通过测量亚甲基蓝在665 nm的颜色强度的降低来监测反应。 Cu 2+离子的分析通过固定时间方法进行。在pH 2.20和32°C下2分钟的给定时间下,检出限为10 ng mL-1,0.4 µg mL-1 Cu2 +的相对标准偏差为3.60%(n = 6)。该方法不受大多数​​干扰的影响,并且还报道了各种离子对Cu2 +测定的影响。所提出的方法实际上是特定于铜的,并且已经令人满意地应用于铜电线样品和药品中的测定。结果也通过原子吸收光谱技术(AAS)验证。