首页> 外文期刊>Analytical Sciences >Determination of Iodine and Bromine Compounds by Ion Chromatography/Dynamic Reaction Cell Inductively Coupled Plasma Mass Spectrometry
【24h】

Determination of Iodine and Bromine Compounds by Ion Chromatography/Dynamic Reaction Cell Inductively Coupled Plasma Mass Spectrometry

机译:离子色谱/动态反应池电感耦合等离子体质谱法测定碘和溴化合物

获取原文
           

摘要

An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic detector for the speciation of iodine and bromine. Gradient elution using NH4NO3 at pH 10 allowed the chromatographic separation of ionic iodine (I- and IO3-) and bromine (Br- and BrO3-) species in less than 8 min. Effluents from the ion-exchange column were delivered to the nebulization system of ICP-MS for the determination of I and Br. The potentially interfering 38Ar40ArH+ and 40Ar40ArH+ at the bromine masses m/z 79 and 81 were significantly reduced in intensity (by approximately two orders of magnitude) by using 0.6 mL min-1 O2 as a reactive cell gas in the dynamic reaction cell (DRC). Moreover, the signal-to-background ratio at iodine mass m/z 127 increased significantly when O2 was used as the reaction gas. The detection limits were in the range of 0.001 - 0.002 and 0.03 - 0.04 ng mL-1 for various I and Br compounds, respectively, based on the peak height. The relative standard deviation of the peak areas for five injections of a 2 ng mL-1 I-, IO3- and 20 ng mL-1 Br-, BrO3- mixture was in the range of 3 - 4%. The concentrations of I and Br compounds have been determined in selected water and urine samples. The spike recoveries were in the range of 94 - 102% for all of the determinations. This method has also been applied to determine various I and Br compounds in an NIST RM 8435 whole-milk powder reference material and a seaweed sample obtained locally. A microwave-assisted extraction method was used to extract these compounds, which were quantitatively leached with a 10% mass/volume (m/v) tetramethylammonium hydroxide (TMAH) solution in a focused microwave field within a period of 6 min. The major components of I and Br in milk powder and seaweed were I- and Br-.
机译:电感耦合等离子体质谱仪(ICP-MS)被用作离子色谱检测器,用于碘和溴的形态分析。使用pH值为10的NH4NO3梯度洗脱,可在8分钟内完成离子碘(I-和IO3-)和溴(Br-和BrO3-)的色谱分离。来自离子交换柱的流出物被送至ICP-MS雾化系统,用于测定I和Br。通过在动态反应池(DRC)中使用0.6 mL min-1 O2作为反应池气体,在溴质量数m / z 79和81下潜在干扰的38Ar40ArH +和40Ar40ArH +的强度显着降低(降低了两个数量级) 。此外,当使用O2作为反应气体时,碘质量m / z 127时的信噪比显着增加。基于峰高,各种I和Br化合物的检出限分别在0.001-0.002和0.03-0.04 ng mL-1的范围内。五次注射2 ng mL-1 I-,IO3-和20 ng mL-1 Br-,BrO3-混合物的峰面积的相对标准偏差在3-4%的范围内。已在选定的水和尿液样品中确定了I和Br化合物的浓度。所有测定的加标回收率均在94-102%的范围内。该方法也已用于测定NIST RM 8435全脂奶粉标准物质和本地获得的海藻样品中的各种I和Br化合物。使用微波辅助提取方法提取这些化合物,并在6分钟的时间内在聚焦微波场中用10%质量/体积(m / v)的四甲基氢氧化铵(TMAH)溶液定量浸出。奶粉和海藻中I和Br的主要成分是I-和Br-。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号