首页> 外文期刊>Analytical Sciences >Flow-Injection Chemiluminescence Method for Sensitive Determination of Ascorbic Acid in Fruit Juices and Pharmaceutical Samples Using a Luminol–Cetyltrimethylammonium Chloride Reversed Micelle System
【24h】

Flow-Injection Chemiluminescence Method for Sensitive Determination of Ascorbic Acid in Fruit Juices and Pharmaceutical Samples Using a Luminol–Cetyltrimethylammonium Chloride Reversed Micelle System

机译:鲁米诺-鲸蜡基三甲基氯化铵反相胶束系统-流动注射化学发光法测定果汁和药物样品中的抗坏血酸

获取原文
           

摘要

A highly sensitive flow-injection (FI) method was developed for the determination of ascorbic acid using chemiluminescence (CL) based detection. This method involved the following processes: (1) reduction of tetrachloroaurate(III) in hydrochloric acid with ascorbic acid; (2) on-line extraction of the residual Au(III) with rhodamine B from the aqueous hydrochloric acid solution into toluene, followed by the separation of the Au(III)-containing organic phase from the aqueous phase through a microporous Teflon membrane in the flow system; and (3) the measurement of CL produced in a flow cell upon mixing of the extract stream of Au(III) in toluene with luminol in the reversed micellar medium of cetyltrimethylammonium chloride–water in 1-hexanol–cyclohexane, which was injected into a CL reagent stream. In this procedure, a reduction in the CL intensity occurred due to the addition of ascorbic acid to the Au(III) solution. The CL signal of Au(III) decreased with increasing concentration of ascorbic acid in the aqueous sample solution. The proposed procedure allowed the indirect quantitative determination of ascorbic acid in the range of 1.0 × 10~(?12) to 1.0 × 10~(?7) M with a correlation coefficient of 0.987 and relative standard deviation of 2.1% (n = 6) at 1.0 × 10~(?9) M. The proposed FI-CL methodology was successfully applied for quantitative determination of ascorbic acid in fruit juices and pharmaceutical samples.
机译:开发了一种高灵敏的流动注射(FI)方法,用于使用基于化学发光(CL)的检测方法测定抗坏血酸。该方法涉及以下过程:(1)用抗坏血酸在盐酸中还原四氯金酸酯(III); (2)用若丹明B从盐酸水溶液中在线萃取残留的Au(III)到甲苯中,然后通过微孔特氟龙膜从水相中分离出含Au(III)的有机相。流动系统; (3)在十六烷基三甲基氯化铵-水在1-己醇-环己烷中的反胶束介质中,将Au(III)在甲苯中的萃取物流与鲁米诺混合后,在流通池中产生的CL的测量,然后将其注入CL试剂流。在此过程中,由于向Au(III)溶液中添加了抗坏血酸,导致CL强度降低。随着样品水溶液中抗坏血酸浓度的增加,Au(III)的CL信号降低。拟议的程序允许间接定量测定1.0×10〜(?12)至1.0×10〜(?7)M范围内的抗坏血酸,相关系数为0.987,相对标准偏差为2.1%( n = 6)在1.0×10〜(?9)M时。所提出的FI-CL方法已成功地用于果汁和药物样品中抗坏血酸的定量测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号