An on-line flow-injection spectrophotometric method coupled with supported liquid membrane enrichment was developed to determine trace Hg(II) in water. Tributyl phosphate (TBP) dissolved in kerosene was used as the flow carrier in a supported liquid membrane extraction system. The effect of various parameters on Hg(II) measurement was investigated. The optimum conditions were determined as 20% TBP in the membrane phase, 0.02 mol La?’1 NaOH in the accepting phase, 0.8 mol La?’1 HCl in the feeding phase, 0.2 ??m PTFE membrane in the enrichment process, and 20 min enrichment time. Under these optimum conditions, the linear range for Hg(II) measurement was from 0.2 to 30 ??g La?’1 with a detection limit of 0.06 ??g La?’1. Additionally, we demonstrated that this system can be used to determine trace Hg(II) in wastewater.
机译:建立了在线流动注射分光光度法与支持的液膜富集相结合的方法,用于测定水中的痕量汞(II)。溶解在煤油中的磷酸三丁酯(TBP)在负载型液膜萃取系统中用作流动载体。研究了各种参数对汞(II)测量的影响。确定了最佳条件:膜相中的TBP为20%,接受相中0.02 mol La?1'1 NaOH,进料相中0.8 mol La?'1 HCl,富集过程中0.2?m PTFE膜和浓缩时间20分钟。在这些最佳条件下,Hg(II)测量的线性范围为0.2到30 ?? g La?'1,检出限为0.06 ?? g La?'1。此外,我们证明了该系统可用于测定废水中的痕量Hg(II)。