首页> 外文期刊>Analytical methods >Amperometric cholesterol biosensor based on zinc oxide films on a silver nanowire–graphene oxide modified electrode
【24h】

Amperometric cholesterol biosensor based on zinc oxide films on a silver nanowire–graphene oxide modified electrode

机译:基于纳米银-氧化石墨烯修饰电极上氧化锌膜的安培胆固醇生物传感器

获取原文
           

摘要

A highly sensitive and selective cholesterol biosensor is successfully fabricated in this work. Due to excellent conductivity and catalytic activity, silver nanowires (AgNWs) and zinc oxide (ZnO) are modified on an indium tin oxide (ITO) electrode with graphene oxide (GO) and chitosan (CS) to construct the novel amperometric biosensor. The composite of AgNWa€“ZnO successfully enhanced electron communication, and the electrochemical performances of the ChOx/ZnO/Ag/GOa€“CS/ITO electrode were investigated via scanning electron microscopy (SEM), cyclic voltammetry (CV) and impedance measurements. The linear response to cholesterol in the range of the fabricated biosensor is 0.25a€“400 mg dLa?’1 (6.5 ??M to 10 mM) with a sensitivity of 9.2 ??A ??Ma?’1 cma?’2. Moreover, the limit of detection (LOD) is 0.287 ??M (S/N = 3), and the Michaelisa€“Menten constant is calculated to be about 0.295 ??M in 0.1 M phosphate buffer solution (pH 7).
机译:这项工作成功地制造出了高灵敏度和选择性的胆固醇生物传感器。由于出色的导电性和催化活性,银纳米线(AgNWs)和氧化锌(ZnO)在氧化铟锡(ITO)电极上被氧化石墨烯(GO)和壳聚糖(CS)修饰,从而构建了新型的安培生物传感器。 AgNWa·ZnO复合材料成功地增强了电子交流,并通过扫描电子显微镜(SEM),循环伏安法(CV)和阻抗测量研究了ChOx / ZnO / Ag / GOaCS / ITO电极的电化学性能。在制造的生物传感器范围内,对胆固醇的线性响应为0.25a?400 mg dLa?'1(6.5?M至10 mM),灵敏度为9.2?A?Ma?1?cma?'2。 。此外,检出限(LOD)为0.287ΔM(S / N = 3),在0.1 M磷酸盐缓冲溶液(pH 7)中,迈克尔沙门汀常数被计算为约0.295ΔM。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号