A post-column reaction-ion chromatography analyzer (PCR-IC) with automated internal standardization (IS) has been optimized to determine nine haloacetic acid (HAAs) species in drinking water while operating in near real-time with a one hour analysis time. The IS-PCR-IC method requires minimal sample preparation that consists of passing water samples through cartridges to remove anions and introducing the pretreated samples into the on-line channel of the automated instrumentation. Two sets of water samples have been analyzed and method detection limit (MDL), accuracy and precision measurements have been conducted prior to the water sample analysis. The experimental MDL values for the HAA species ranged from 1.4 to 7.8 μg L?1; the accuracy ranged from 75.9 to 112%; and the precision ranged from 6.2 to 34.6%. The concentration of each HAA and the Total HAAs found in these water samples were determined using internal standardization and the results were compared to USEPA Method 552.3. The bias estimates between these two methods for Total HAA9 range from ?8.3 to 12.5 μg L?1...
机译:带有自动内标(IS)的柱后反应离子色谱分析仪(PCR-IC)已进行优化,可确定饮用水中的9种卤乙酸(HAAs)种类,同时以近一小时的分析时间实时进行操作。 IS-PCR-IC方法需要最少的样品前处理,包括将水样品通过小柱以除去阴离子,然后将预处理后的样品引入自动化仪器的在线通道。分析了两组水样,并在分析水样之前进行了方法检出限(MDL),准确性和精密度测量。 HAA物种的实验MDL值在1.4至7.8μgL?1之间;准确度在75.9至112%之间;精度范围为6.2至34.6%。使用内标法确定这些水样中发现的每种HAA的浓度和总HAA的浓度,并将结果与​​USEPA方法552.3进行比较。两种方法对Total HAA9的偏倚估计范围为8.3至12.5μgL?1 ...

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号