In this work, the electrocatalytic oxidation of some dopaminergic drugs such as selegiline (SEL) and pramipexole (PX) was carried out, for the first time with a nickel nanoparticle modified carbon paste electrode (Ni-NP/MCPE) using cyclic voltammetry, chronoamperometry, chronocoulometry, and amperometry methods. At first, nickel nanoparticles were synthesized by a non-aqueous polyol method and then these nanoparticles were mixed with graphite powder to form a modified carbon paste electrode. The as-prepared modified electrode was characterized by using SEM images. The images from the surface of the electrode indicate that these particles were formed uniformly with an average size of 50 nm. In the presence of 0.1 M NaOH, a good redox behavior of the Ni(III)/Ni(II) couple at the surface of the electrode can be observed. SEL and PX were successfully oxidized at the surface of this modified electrode. The electrocatalytic oxidation peak currents of these drugs were linearly dependent on their concentrations. The detection limit, slope, and correlation coefficient were calculated to be 4.0 ?— 10a?’6, 4.84 ?— 10a?’2, and 0.9951 for SEL and also 4.5 ?— 10a?’8, 4.46 ?— 10a?’2, and 0.9948, respectively, for PX. The proposed sensor exhibited a high sensitivity and good selectivity, and was successfully applied for clinical evaluation of SEL and PX.
机译:在这项工作中,使用循环伏安法,计时电流法,首次使用镍纳米粒子修饰的碳糊电极(Ni-NP / MCPE)对一些多巴胺能药物,例如司来吉兰(SEL)和普拉克索(PX)进行了电催化氧化。 ,计时库仑法和电流分析法。首先,通过非水多元醇法合成镍纳米粒子,然后将这些纳米粒子与石墨粉混合以形成改性碳糊电极。通过使用SEM图像表征所制备的改性电极。来自电极表面的图像表明,这些颗粒均匀地形成,平均尺寸为50 nm。在0.1 M NaOH的存在下,可以观察到电极表面的Ni(III)/ Ni(II)偶对具有良好的氧化还原行为。 SEL和PX在此修饰电极的表面成功氧化。这些药物的电催化氧化峰值电流与浓度成线性关系。计算出的检出限,斜率和相关系数分别为4.0?-10a?'6、4.84?-10a?'2和0.9951(对于SEL)以及4.5?-10a?'8、4.46?-10a?'2 ,分别为PX和0.9948。所提出的传感器表现出高灵敏度和良好的选择性,并已成功地用于SEL和PX的临床评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号