首页> 外文期刊>Analytical methods >A high-throughput method for multi-element determination in green coffee beans using diluted nitric acid and ultrasound energy
【24h】

A high-throughput method for multi-element determination in green coffee beans using diluted nitric acid and ultrasound energy

机译:利用稀硝酸和超声能量测定生咖啡豆中多元素的高通量方法

获取原文
           

摘要

Different coffee varieties have been developed due to climatic particularities in Brazil; these varieties may have to overcome rigorous quality control that includes, among other, elemental determination, for which sample preparation is a critical step. Hence, this work describes the multivariate development of a straightforward method based on the use of diluted nitric acid and ultrasound-assisted extraction (UAE) followed by determination using inductively coupled plasma optical emission spectrometry and application for multi-element determination in newly developed varieties of coffee. The extraction time and HNO3 concentration were optimized. Quantitative recoveries were obtained using 15 min of extraction time and 0.6 mol L?1 HNO3. 0.48 mol L?1 HCl was added after the extraction procedure in order to stabilize the analytes in the diluted HNO3 solution. The accuracy of the method was evaluated comparing the proposed method with microwave-assisted digestion (MAD) and recovery tests. The UAE results were in agreement with those obtained by MAD according to a t-test at the 95% confidence level. A total of thirty-five coffee bean samples were analyzed using the proposed method. The results showed a variation in concentration from 0.2 to 4.5 μg g?1 for Ba, 1507 to 2576 μg g?1 for Ca, 5 to 30 μg g?1 for Cu, 17 to 44 μg g?1 for Fe, 30?771 to 55?741 μg g?1 for K, 2005 to 3327 μg g?1 for Mg, 12.1 to 148.8 μg g?1 for Mn, 1.0 to 7.6 μg g?1 for Sr, 1105 to 2766 μg g?1 for P, and 4 to 12 μg g?1 for Zn. It was also possible to obtain the correlation of elements and the variation in the elemental content, which was related to the cultivars, geographic location and year.
机译:由于巴西的气候特点,已经开发了不同的咖啡品种。这些品种可能必须克服严格的质量控制,其中包括元素测定,其中样品制备是关键步骤。因此,这项工作描述了基于稀硝酸和超声辅助萃取(UAE)的直接方法的多变量开发,然后使用感应耦合等离子体光发射光谱法进行测定,并将其用于新开发品种中的多元素测定。咖啡。优化了提取时间和硝酸浓度。使用15分钟的萃取时间和0.6 mol L?1 HNO3可获得定量回收率。萃取步骤后加入0.48 mol L?1 HCl,以稳定稀释的HNO3溶液中的分析物。将该方法与微波辅助消解(MAD)和回收率测试进行了比较,评估了该方法的准确性。阿联酋的结果与MAD在95%置信水平下根据t检验得出的结果一致。使用所提出的方法对总共35个咖啡豆样品进行了分析。结果表明,Ba的浓度变化范围为0.2至4.5μgg?1,Ca为1507至2576μgg?1,Cu为5至30μgg?1,Fe为17至44μgg?1,Fe为30?g。 K为771至55?741μgg?1,Mg为2005至3327μgg?1,Mn为12.1至148.8μgg?1,Sr为1.0至7.6μgg?1,1105至2766μgg?1 P,Zn为4至12μgg?1。还可能获得元素的相关性和元素含量的变化,这与品种,地理位置和年份有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号