首页> 外文期刊>Analytical methods >An autonomous batch analyzer for the determination of trace ammonium in natural waters using fluorometric detection
【24h】

An autonomous batch analyzer for the determination of trace ammonium in natural waters using fluorometric detection

机译:自动化批处理分析仪,用于使用荧光检测法测定天然水中的痕量铵

获取原文
           

摘要

An autonomous batch analyzer (ABA) is described for the measurement of ammonium in natural waters. The system combines previously described batch analysis and continuous flow analysis methods. With its simpler design, the system is robust, flexible, inexpensive, and requires minimal maintenance. The sampling frequency is ca. 8 h?1 and the limit of detection ca. 1 nM which is comparable to the most sensitive flow through or batch analysis methods previously described. Reproducibility is 0.6% (n = 10) at an ammonium level of 200 nM. There are three working ranges: 5–1000 nM, 20–4000 nM, and 0.2–25 μM. In addition, the system produces a calibration curve by autodilution from a single stock standard solution with the same accuracy as traditional manual calibration methods. Representative field data and comparisons with standard EPA methods confirm the utility of the ABA...
机译:描述了一种自动批处理分析仪(ABA),用于测量天然水中的铵。该系统结合了先前描述的批处理分析和连续流分析方法。通过其更简单的设计,该系统既坚固,灵活,廉价又需要最少的维护。采样频率约为。 8 h?1和检出限ca. 1 nM,可与之前所述的最灵敏的流通或批量分析方法相提并论。铵水平为200 nM时,重现性为0.6%(n = 10)。有三个工作范围:5-1000 nM,20-4000 nM和0.2-25μM。此外,该系统通过自动稀释从单一储备标准溶液中生成校准曲线,其准确性与传统的手动校准方法相同。代表性的现场数据以及与标准EPA方法的比较证实了ABA的实用性。