首页> 外文期刊>American Journal of Materials Science >Effect of High Temperature on Rear Pass Boiler Tubes in Coal-Fired Power Plant
【24h】

Effect of High Temperature on Rear Pass Boiler Tubes in Coal-Fired Power Plant

机译:高温对火力发电厂后通道锅炉管的影响

获取原文
           

摘要

This work presents the investigations on three sample boiler tubes in the rear pass area (low temperature reheater 1 (LTR1)(A210-A1), intermediate temperature superheater (ITS)(A210-C) and economizer tubes) ) (A210-C) of a coal-fired power plant in Malaysia, which had been replaced during major overhaul in January 2014 after running for about 11 years. Visual inspections, chemical analysis on deposits, metallurgical examinations and creep analysis on the tubes were carried out. Findings from the investigation were used to determine the tubes condition metallurgically before the removal. The results show that the relatively high temperature at the area pass area did not affect the metallurgical property of the tubes.
机译:这项工作提出了对在后通区域的三个样品锅炉管(低温再热器1(LTR1)(A210-A1),中温过热器(ITS)(A210-C)和省煤器管)的研究(A210-C)是马来西亚一家燃煤发电厂的一部分,在运行约11年后于2014年1月进行了大修。进行了目视检查,沉积物的化学分析,冶金检查和试管的蠕变分析。从调查中获得的结果用于在拆卸之前冶金确定管子的状况。结果表明,在区域通过区域的相对较高的温度不会影响管的冶金性能。