The aim of the present work was to know the facts of Methyl Isocyanate (MIC) gas leakage and burst of its storage tank. The failure of the tank was evaluated based on the Tresca, von Mises criteria, Weibull criteria. The significance of chlorine induced corrosion and temperature derating factor were recognized using Taguchi techniques. The bursting pressure of the storage tank was highly dependent on the temperature derating factor and the crack depth. The reasons for the failure of experimental storage tanks used in the present work would satisfy the causes for the leakage of Methyl isocyanate gas and failure of the storage tank during the Bhopal gas disaster.
机译:本工作的目的是了解异氰酸甲酯(MIC)气体泄漏和储罐爆裂的事实。根据Tresca,von Mises标准和Weibull标准评估储罐的故障。使用Taguchi技术已经认识到氯引起的腐蚀和温度降额因数的重要性。储罐的破裂压力高度取决于温度降额系数和裂纹深度。目前工作中使用的实验储罐发生故障的原因将能够满足在博帕尔天然气灾难期间异氰酸甲酯气体泄漏和储罐发生故障的原因。