首页> 外文期刊>American Journal of Engineering Research >A Novel Harmonic-Based Phase-Shifted Control Method to Regulate The Transferred Power
【24h】

A Novel Harmonic-Based Phase-Shifted Control Method to Regulate The Transferred Power

机译:一种基于谐波的移相控制功率调节新方法

获取原文
           

摘要

over a wide range of load the power is regulated with high efficien cy by inductively coupled power transfer system. In this paper a novel harmonic based phase-shifted control method is proposed. With this method, the resonant inverter output voltage is employed to regulate the output power. By changing the phase-shifted angle of inverter the output power is regulated. The switching frequency is much lower than the fundamental frequency which is different from conventional approaches; therefore the switching losses are very less. The principle of operation, switching strategy and the effect of dead time ha s all been presented. Experimental results says that the proposed power regulate method can achieve improvement at the light load condition.
机译:在很宽的负载范围内,通过感应耦合的功率传输系统可以高效地调节功率。本文提出了一种新的基于谐波的相移控制方法。通过这种方法,采用了谐振逆变器输出电压来调节输出功率。通过改变逆变器的相移角,可以调节输出功率。开关频率远低于基频,这与传统方法不同;因此开关损耗非常小。提出了工作原理,切换策略和空载时间的影响。实验结果表明,提出的功率调节方法可以在轻载条件下实现改进。