首页> 外文期刊>American Journal of Biomedical and Life Sciences >The Effect of Implant Neck Design on the Crestal Bone Levels that Support the Tissue Around the Implant - Restoration
【24h】

The Effect of Implant Neck Design on the Crestal Bone Levels that Support the Tissue Around the Implant - Restoration

机译:种植体颈部设计对支持种植体周围组织的Around骨水平的影响

获取原文
       

摘要

This research aims to evaluate the impact of the shape of the implant neck on the level of crestal bone surrounding it. Dental implant surgeries were performed, and prosthesis were placed over (28) implants in six jaws for five patients (5 upper jaws and 1 lower jaw). These dental implant surgeries were performed on the jaws such that one of the sides received 2 or 3 implants from the BICON system with beveled neck, while the opposite side received the same number of implants from the ONB system from IDI with non-beveled neck. The implant-restorations were then performed following complete osseointegration. The patients were observed via periodic panoramic radiographs starting from the day the prosthesis were placed, then 3 months after the restoration, 6 months after the restoration and 18 months after the restoration. The distance between the implant neck and the point of contact of the crestal bone with the implant neck (mesial and distal) was measured for each implant using periodic panoramic radiographs taken for every patient. The results revealed the occurrence of periimplant crestal bone loss, known as the saucerization phenomenon. Independent samples T-test was conducted to compare the mean bone loss with both types of implants mentioned above. The results of the study did not show any statistically significant differences in the early stages of the restoration/prosthesis. Yet, after 6 months and up to 18 months post restoration, statistically significant differences emerged verifying that the peri-implant bone loss occurring in implants with a beveled neck was less than that occurring around implants with a non-beveled neck, confirming the incidence of an initial bone loss following the restoration in all cases. This research revealed that the design of the implant yields better esthetic results in the presence of a bevel in the implant neck, taking into consideration the occurrence of a definite bone loss.
机译:这项研究旨在评估植入物颈部形状对其周围牙槽骨水平的影响。进行了牙科种植手术,并将假体放置在六个颌中的(28个)种植体上,供五名患者使用(5个上颌和1个下颌)。这些牙科植入物手术是在颌骨上进行的,使得一侧中的一者从带有斜角颈部的BICON系统中接收2到3个植入物,而另一侧则从IDI的非斜角颈部接收来自ONB系统的相同数量的植入物。然后在完全骨整合后进行植入物修复。从放置假体的那天开始,然后在修复后3个月,修复后6个月和修复后18个月,通过定期的全景X射线照片对患者进行观察。使用每位患者拍摄的定期全景X射线照片测量每种植入物的植入物颈部与牙槽骨与植入物颈部的接触点之间的距离(中间和远端)。结果显示发生了种植体周围牙槽骨的丢失,称为碟化现象。进行独立样本T检验以比较上述两种植入物的平均骨丢失。研究结果在修复/假体的早期没有显示任何统计学上的显着差异。然而,在修复后6个月至18个月内,出现了统计学上的显着差异,这证实了在有斜角颈部的种植体中发生的种植体周围骨丢失少于在无斜角颈部的种植体周围发生的种植体骨丢失,从而证实了在所有情况下,修复后都会出现最初的骨丢失。这项研究表明,考虑到一定的骨质流失,在种植体颈部存在斜面的情况下,种植体的设计可获得更好的美学效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号