The removal of chromium (VI) from aqueous solutions by Donnan dialysis has been investigated in this paper. In this process, two anion-exchange membranes (AEMs) were used: Selemion? AMV and Neosepta? AFN. The amount of chromium (VI) removed was determined in terms of the following parameters: initial concentration of chromium (VI), type of anion-exchange membrane, concentration of counter-ion and magnetic stirring rate. A 24 full factorial design analysis was performed to screen the parameters affecting the Cr (VI) removal efficiency. Using the experimental results, a linear mathematical model representing the influence of the different parameters as well as their interactions was obtained. Analysis of the variance (ANOVA), the F-test and the student’s test shows that the type of anion-exchange membrane is the most significant parameter affecting the chromium (VI) removal. The statistical analysis of the experimental data assumes it to be a normal distribution.
机译:本文对Donnan渗析法从水溶液中去除铬(VI)进行了研究。在此过程中,使用了两个阴离子交换膜(AEM):Selemion? AMV和Neosepta? AFN。根据以下参数确定去除的铬(VI)的量:铬(VI)的初始浓度,阴离子交换膜的类型,抗衡离子的浓度和磁力搅拌速度。进行了24次全因子设计分析,以筛选影响Cr(VI)去除效率的参数。使用实验结果,获得了代表不同参数及其相互作用的线性数学模型。方差分析(ANOVA),F检验和学生检验表明,阴离子交换膜的类型是影响铬(VI)去除率的最重要参数。实验数据的统计分析假定它是正态分布。

著录项