首页> 外文期刊>Advances in Physics Theories and Applications >Study The effect of the shields movement and its thickness in detection efficiency By Using Scintillation Detector NaI(Tl)
【24h】

Study The effect of the shields movement and its thickness in detection efficiency By Using Scintillation Detector NaI(Tl)

机译:利用闪烁探测器NaI(Tl)研究盾构移动及其厚度对探测效率的影响

获取原文
           

摘要

In the present work, detection efficiency has been Calculated for the scintillation detector NaI(Tl) (2? x 2?) and radioactive source Cs-137, and by using absorbent material (shield) aluminum and iron between radioactive source and detector for thickness ( 0.1 – 1 ) cm. The effect of the shield movement and its thickness and also the speed of the shield movement on the detection efficiency have been studied. It is found that detection efficiency decrease with a moving shield and with the thickness of the shield. It is found, also that detection efficiency decrease with the speed of the shield movement for all shields aluminum and iron.
机译:在本工作中,已经计算出了闪烁探测器NaI(Tl)(2?x 2?)和放射源Cs-137,以及在放射源和探测器之间使用吸收性材料(屏蔽)铝和铁的厚度,从而计算出探测效率(0.1 – 1)厘米。研究了盾牌运动及其厚度以及盾牌运动速度对检测效率的影响。发现随着移动的屏蔽物和屏蔽物的厚度,检测效率降低。还发现,对于所有铝和铁屏蔽罩,检测效率都随着屏蔽罩运动的速度而降低。