...
首页> 外文期刊>African journal of urology >Use of the adjustable trans-obturator male sling system for the treatment of male incontinence. An initial experience
【24h】

Use of the adjustable trans-obturator male sling system for the treatment of male incontinence. An initial experience

机译:可调式透闭式男性吊索系统用于治疗男性失禁。初步经验

获取原文
           

摘要

Objective To evaluate the safety and efficacy of the “Adjustable Trans-Obturator Male Sling System (ATOMS)” as a new surgical technique for the treatment of different types of male urinary incontinence. Subjects and methods Between March 2012 and December 2013, 9 patients with a mean age of 56 (range 15–74) years were operated for urinary incontinence using the ATOMS system. Incontinence had developed following bladder exstrophy repair in 2, after radical cystectomy with construction of an orthotopic neobladder in 3, after transvesical open prostatectomy in one and after radical prostatectomy in 3 patients. Preoperative evaluation included a detailed medical history, physical examination, 24-h pad tests, urodynamic assessment and sonography. Results The mean number of pads used preoperatively was 4.6 (range 3–6). The mean operative time was 45 (range 36–50) min. No intraoperative complications were encountered. The mean hospital stay was 3.8 (range 3–6) days. Transient perineal/scrotal pain was observed in 6 patients (66.7%) and controlled with non-opioid analgesics. There were no perineal infections; however, two port infections occurred (22.2%) and repositioning of the port was done in these cases. At a mean follow-up of 9 (range 6–12) months, the overall success rate was 100% with 77.8% of the patients being completely dry (0 pads per 24 h) and 22.2% using less than 2 pads per 24 h. Conclusions Our early experience demonstrated that the ATOMS system may be a safe and effective procedure for the treatment of male urinary incontinence. It has the advantage of being feasible any time after an operation when necessary. However, long-term follow-up on a large number of cases is required to ensure its long-term efficacy and safety.
机译:目的评估“可调式经闭塞男性吊索系统(ATOMS)”作为治疗不同类型男性尿失禁的一种新手术技术的安全性和有效性。对象和方法2012年3月至2013年12月之间,使用ATOMS系统对9例平均年龄为56岁(15-74岁)的患者进行了尿失禁手术。膀胱外翻修复术后2例发生尿失禁,根治性膀胱切除术3例原位新膀胱造模术,膀胱开放前列腺切除术1例,根治性前列腺切除术3例。术前评估包括详细的病史,体格检查,24小时垫试验,尿动力学评估和超声检查。结果术前平均使用的护垫数量为4.6(范围3–6)。平均手术时间为45分钟(36-50分钟)。术中未见并发症。平均住院时间为3.8天(3-6天)。 6例患者(66.7%)观察到会阴/阴囊短暂性疼痛,并使用非阿片类镇痛药进行控制。没有会阴部感染;但是,在这些情况下发生了两次端口感染(占22.2%),并且已经对端口进行了重新定位。平均随访9个月(6至12个月),总成功率为100%,其中77.8%的患者完全干燥(每24小时0个垫子),22.2%的患者每24小时使用2个垫子。结论我们的早期经验表明,ATOMS系统可能是治疗男性尿失禁的安全有效方法。其优点是必要时在手术后的任何时候都是可行的。但是,需要对大量病例进行长期随访,以确保其长期疗效和安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号