...
首页> 外文期刊>African Journal of Laboratory Medicine >Using laboratory data to categorise CD4 laboratory turn-around-time performance across a national programme
【24h】

Using laboratory data to categorise CD4 laboratory turn-around-time performance across a national programme

机译:使用实验室数据对国家计划中CD4实验室周转时间的表现进行分类

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background and objective: ?The National Health Laboratory Service provides CD4 testing through an integrated tiered service delivery model with a target laboratory turn-around time (TAT) of 48 h. Mean TAT provides insight into national CD4 laboratory performance. However, it is not sensitive enough to identify inefficiencies of outlying laboratories or predict the percentage of samples meeting the TAT target. The aim of this study was to describe the use of the median, 75th percentile and percentage within target of laboratory TAT data to categorise laboratory performance. ? Methods: ?Retrospective CD4 laboratory data for 2015–2016 fiscal year were extracted from the corporate data warehouse. The laboratory TAT distribution and percentage of samples within the 48 h target were assessed. A scatter plot was used to categorise laboratory performance into four quadrants using both the percentage within target and 75th percentile TAT. The laboratory performance was labelled good, satisfactory or poor. ? Results: ?TAT data reported a positive skew with a mode of 13 h and a median of 17 h and 75th percentile of 25 h. Overall, 93.2% of CD4 samples had a laboratory TAT of less than 48 h. 48 out of 52 laboratories reported good TAT performance, i.e. percentage within target 85% and 75th percentile ≤ 48 h, with two categorised as satisfactory (one parameter met), and two as poor performing laboratories (failed both parameters). ? Conclusion: ?This study demonstrated the feasibility of utilising laboratory data to categorise laboratory performance. Using the quadrant approach for TAT data, laboratories that need interventions can be highlighted for root cause analysis assessment.
机译:背景和目标:?国家卫生实验室服务中心通过集成的分层服务交付模型提供CD4测试,目标实验室周转时间(TAT)为48小时。 TAT平均值可以洞悉国家CD4实验室的性能。但是,识别外围实验室的低效率或预测达到TAT目标的样品百分比不够敏感。这项研究的目的是描述在实验室TAT数据目标范围内使用中位数,第75个百分位数和百分比来对实验室性能进行分类。 ?方法:?从公司数据仓库中提取2015-2016财年的回顾性CD4实验室数据。评估了48小时目标内的实验室TAT分布和样品百分比。使用散点图将实验室绩效按目标范围内的百分比和第75个百分位数的TAT分为四个象限。实验室性能被标记为好,满意或差。 ?结果:ΔTAT数据报告偏斜为正,模式为13小时,中位数为17小时,第75个百分位数为25小时。总体而言,93.2%的CD4样品的实验室TAT少于48小时。 52个实验室中有48个报告的TAT性能良好,即目标范围内的百分比> 85%,第75个百分位数≤48小时,其中两个分类为令人满意(满足一个参数),两个分类为性能不佳的实验室(两个参数均未通过)。 ?结论:这项研究证明了利用实验室数据对实验室绩效进行分类的可行性。使用象限方法处理TAT数据,可以突出显示需要干预的实验室进行根本原因分析评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号