首页> 外文期刊>African Journal of Pure and Applied Chemistry >Separation of lead(II) paraffin-embedded tissues from liver loggerhead turtles specimens by organic-solution-processable functionalized-nano graphene prior to determination by flame atomic absorption spectrometry (FAAS)
【24h】

Separation of lead(II) paraffin-embedded tissues from liver loggerhead turtles specimens by organic-solution-processable functionalized-nano graphene prior to determination by flame atomic absorption spectrometry (FAAS)

机译:火焰原子吸收光谱法(FAAS)测定前,通过有机溶液可处理的功能化纳米石墨烯从肝龟标本中分离石蜡包埋的铅(II)组织。

获取原文
           

摘要

A novel and selective method for the fast determination of trace amounts of Pb(II) ions in liver loggerhead turtles specimens has been developed. A reliable and rapid method for preconcentration and modification of organic-solution-processable functionalized-nano graphene with Isopropyl 2-[(isopropoxy carbothioyl) disulfanyl] ethanethioate (IIDE) in order to prepare an effective sorbent for the preconcentration and determination of lead. The sorption capacity of modified organic-solution-processable functionalized-nano graphene (IIDE MS) was 82.34 mg.g-1and the optimum pH for the quantitative recovery of lead was found as 5.3. The optimum flow rate, sorbent amount and sample volume were 8 ml.min-1, 300 mg and 50 ml, respectively. 10 ml of 0.1 mol.L-1HCl was the most suitable eluent. The recommended method is simple and reliable for the determination of lead without any notable matrix effect and successfully applied to environmental water samples. The limit of detection of the proposed method is 7.5 ng/ml. The method was applied to the extraction and recovery of Pb(II) in different water samples. In the present study, we report the application of preconcentration techniques still continues increasingly for trace metal determinations by flame atomic absorption spectrometry (FAAS) for quantification of lead in Formalin-fixed paraffin-embedded (FFPE) tissues from liver loggerhead turtles. This method exhibits the superiority in compared to the other adsorption reagents because of the fact that there is no necessity of any complexing reagent and optimum pH of solution presents in acidic media. In this method, the relative standard deviation (RSD) of 2.7%.
机译:开发了一种新颖的,选择性的方法,可以快速测定肝龟标本中的痕量Pb(II)离子。一种可靠,快速的方法,可以使用2-[((异丙氧基碳硫基)二硫烷基]乙硫醇异丙酯(IIDE)对有机溶液可处理的官能化纳米石墨烯进行预浓缩和改性,从而制备用于预浓缩和测定铅的有效吸附剂。改性的可在有机溶液中处理的功能化纳米石墨烯(IIDE MS)的吸附容量为82.34 mg.g-1,发现铅的定量回收的最佳pH为5.3。最佳流速,吸附剂量和样品量分别为8 ml.min-1、300 mg和50 ml。 10 ml的0.1 mol L-1HCl是最合适的洗脱液。推荐的方法简便,可靠,无需任何明显的基质效应即可测定铅,并成功应用于环境水样。该方法的检出限为7.5 ng / ml。该方法用于不同水样中铅(II)的提取和回收。在本研究中,我们报道通过火焰原子吸收光谱法(FAAS)对富马林固定石蜡包埋的(FFPE)组织中的铅进行定量分析,富集技术在痕量金属测定中的应用仍在继续增长。由于不需要任何络合剂并且酸性介质中溶液的最佳pH值这一事实,与其他吸附剂相比,该方法具有优越性。在这种方法中,相对标准偏差(RSD)为2.7%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号