...
首页> 外文期刊>Acta Medica Academica >The effect of different enamel surface treatments on microleakage of fissure sealants
【24h】

The effect of different enamel surface treatments on microleakage of fissure sealants

机译:不同搪瓷表面处理对裂缝密封胶微渗漏的影响

获取原文

摘要

Objective. The aim of this study was to evaluate the effects of different techniques of surface treatment on the microleakage of fissure sealants in permanent molar teeth in vitro. Materials and methods. 96 extracted impacted human third molars were randomly divided into 8 surface treatment groups (n=12/group) as 1. Er: YAG laser; (Fidelis II, Fotona, Ljubljana, Slovenia) (125 mj, 20Hz). 2. Er: YAG laser + 37% H3PO4 (15s); 3. ER: AG laser + 37% H3PO4+Prime&Bond NT; 4. Er: YAG laser + G Bond; 5. Er: YAG laser + Prime&Bond NT; 6. 37% H3PO4; 7. 37% H3PO4 + Prime &Bond NT; 8. G Bond. Sealant material (Clinpro, 3M ESPE, Seefeld, Germany), was applied into the fissures and light-cured for 20s with LED (Bluephase C5, Ivoclar-Vivadent, Schaan, Liechtenstein). Specimens were subjected to thermocycling (1000×, 5-55°C, dwell time: 15s) and immersed in 0.5% basic fuchsin solution for 24h at 37°C. The samples were sectioned and scored on a 3 point rating scale using a light microscope with a magnification of ×20. One-way analysis of variance was used to analyze data. Multiple comparisons were analyzed using Bonferroni test (p=0.05). Results. Er:YAG laser showed the highest microleakage scores whereas Er YAG laser + 37% H3PO4 showed the lowest. Although 37% H3PO4 group showed higher scores than Er:YAG laser + 37% H3PO4, the difference was not statistically significant. Conclusion. Etching fissures with phosphoric acid is sufficient prior to fissure sealant application.
机译:目的。这项研究的目的是评估不同的表面处理技术对恒磨牙恒牙缝隙密封剂微渗漏的影响。材料和方法。将提取的96颗受影响的人类第三磨牙随机分为8个表面处理组(n = 12 /组),分别为1。 (Fidelis II,Fotona,卢布尔雅那,斯洛文尼亚)(125 mj,20Hz)。 2. Er:YAG激光+ 37%H3PO4(15s); 3. ER:AG激光+ 37%H3PO4 + Prime&Bond NT; 4. Er:YAG激光+ G键; 5. Er:YAG激光+ Prime&Bond NT; 6. 37%H3PO4; 7. 37%H3PO4 + Prime&Bond NT; 8. G键。将密封剂材料(Clinpro,3M ESPE,Seefeld,德国)施加到裂缝中,并用LED(Bluephase C5,Ivoclar-Vivadent,列支敦士登,沙恩)光固化20秒。将样品进行热循环(1000x,5-55℃,停留时间:15s)并在37℃下浸入0.5%碱性品红溶液中24小时。将样品切成薄片,并使用放大倍数为20的光学显微镜以3点等级进行评分。使用单向方差分析来分析数据。使用Bonferroni检验分析多重比较(p = 0.05)。结果。 Er:YAG激光的微漏得分最高,而Er YAG激光+ 37%H3PO4的微漏得分最低。尽管37%的H3PO4组比Er:YAG激光+ 37%的H3PO4得分更高,但差异无统计学意义。结论。在使用裂缝密封胶之前,用磷酸蚀刻裂缝就足够了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号