首页> 外文期刊>Acta orthopaedica. >Quantification of polyethylene degradation in mobile bearing knees: A retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee
【24h】

Quantification of polyethylene degradation in mobile bearing knees: A retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee

机译:定量分析活动性膝关节中聚乙烯的降解:前-后滑行(APG)和旋转平台(RP)低接触应力(LCS)膝盖的检索分析

获取原文
           

摘要

Background ?Routine qualitative observations of more than 850 polyethylene fixed and mobile bearings at our institution have noted minimal wear of mobile bearings. The APG mobile bearing is the most recent design variant of the LCS knee, allows multi-directional movement at the tibiofemoral articulation, and is posterior cruciate sparing. Even though it is difficult to perform, quantitative wear measurement is important in determining the likely longevity of new arthroplasty devices, and is especially relevant because of increasing numbers of new mobile bearing designs. Patients and methods ?We analyzed 10 retrieved APG and 7 retrieved RP tibial bearings (De Puy) with a mean implantation period of 33 (9–70) months. We used coordinate-measuring techniques to quantitatively determine linear penetration, and optical and scanning electron microscopy to assess wear mechanisms qualitatively. Results ?The mean total volume loss (superior and inferior articulations) of the APG and RP designs was 85?mm3/year and 77?mm3/year, respectively. Burnishing was the predominant wear mechanism, and to a lesser extent scratching, abrasion and pitting. Multidirectional scratching and abrasion were noted on the APG inserts inferiorly, whereas there was circumferential scratching on the RP inserts. Interpretation ?Our short-term results for the APG and RP mobile bearing designs are similar and compare more than favorably with reported values for fixedbearing designs. However, increased backside wear due to multidirectional movement may predispose the APG design to greater wear in the long term.
机译:背景?我们机构对850多种聚乙烯固定和移动轴承的常规定性观察表明,移动轴承的磨损最小。 APG移动轴承是LCS膝关节的最新设计变体,可在胫股关节处进行多方向运动,并且保留后十字形。即使很难执行,定量磨损测量对于确定新的关节置换设备的使用寿命也很重要,并且由于新的活动轴承设计数量的增加而特别重要。患者和方法?我们分析了10例取回的APG和7例取回的RP胫骨轴承(De Puy),平均植入期为33(9–70)个月。我们使用坐标测量技术来定量确定线性渗透,并使用光学和扫描电子显微镜定性评估磨损机理。结果?APG和RP设计的平均总体积损失(上下关节)分别为85?mm 3 /年和77?mm 每年3 。抛光是主要的磨损机制,在较小程度上是刮擦,磨损和点蚀。在APG刀片上发现多向刮擦和磨损,而在RP刀片上出现了圆周刮擦。解释?我们对APG和RP移动轴承设计的短期结果相似,并且与固定轴承设计的报告值相比更具优势。但是,由于多方向运动而导致的背面磨损增加,可能会使APG设计长期处于更大的磨损状态。

著录项