首页> 外文期刊>Current Directions in Biomedical Engineering >Implantable electronics of a closed-loop system for controlling prosthetic hands
【24h】

Implantable electronics of a closed-loop system for controlling prosthetic hands

机译:用于控制假手的闭环系统的可植入电子设备

获取原文
           

摘要

This paper presents the design of implantable electronics as a part of a system for prosthetic hand control. Purpose of the implant is the sensing of electrical signals originating from biological tissue and the actuation of the same, therefore closing the loop and allowing for an improved control of the prosthetic hand. The implant contains two integrated circuits for eight channel EMG monitoring and four channel stimulation, respectively. An on-board microcontroller allows for local pre-processing. All intracorporeal to extracorporeal communications are running through and are directed by the main processing platform. The external components of the control system include, in addition to the main processing and control platform, the inductive power transfer circuits and the pressure sensors for the sensory feedback. Different assembly and encapsulation options are taken into account for the implantable electronics and are unified in a single PCB design.
机译:本文介绍了植入式电子设备的设计,将其作为假手控制系统的一部分。植入物的目的是感测源自生物组织的电信号并对其进行致动,因此闭合环并允许对假手进行更好的控制。植入物包含两个集成电路,分别用于八通道EMG监测和四通道刺激。板载微控制器可以进行本地预处理。所有体内到体外的通信都在运行,并由主处理平台指导。除主处理和控制平台外,控制系统的外部组件还包括感应功率传输电路和用于感官反馈的压力传感器。植入式电子设备考虑了不同的组装和封装选项,并统一在单个PCB设计中。