...
首页> 外文期刊>Contemporary Clinical Dentistry >Shear bond strength of composite resin to dentin after application of cavity disinfectants – SEM study
【24h】

Shear bond strength of composite resin to dentin after application of cavity disinfectants – SEM study

机译:应用腔体消毒剂后复合树脂与牙本质的剪切粘结强度– SEM研究

获取原文
           

摘要

Aim:The aim was to evaluate the effect of different cavity disinfectants on dentin bond strengths of composite resin applied with two different adhesive systems.Materials and Methods:Two-hundred mandibular molars were sectioned parallel to the occlusal surface to expose dentin in the midcoronal one-third. The dentinal surfaces were polished with waterproof-polishing papers. The specimens were randomly divided into five groups of 40 teeth each as follows: group 1(control) -- specimens were not treated with any cavity disinfectants. Groups 2--5 (experimental groups) -- dentin surfaces were treated with the following cavity disinfectants, respectively; 2% chlorhexidine solution, 0.1% benzalkonium chloride-based disinfectant, 1% chlorhexidine gel, and an iodine potassium iodide/copper sulfate-based disinfectant. The specimens were then randomly divided into two subgroups including 20 teeth each to evaluate the effect of different bonding systems. Dentin bonding systems were applied to the dentin surfaces and the composite buildups were done. After the specimens were stored in an incubator for 24 hours, the shear bond strength was measured at a crosshead speed of 1 mm/min. The specimens were then statistically analyzed.Statistical Analysis Used:One way analysis of variance and Tukey-HSD tests were used.Results:There was no significant difference between chlorhexidine gel and control groups regardless of the type of the bonding agent used (P>0.05). On the other hand, pretreatment with benzalkonium chloride-based, iodine potassium iodide/copper sulfate-based disinfectants or chlorhexidine solutions had a negative effect on the shear bond strength of self-etching bonding systems.Conclusions:The findings of this study suggest that when benzalkonium chloride-based, iodine potassium iodide/copper sulfate-based disinfectants or chlorhexidine solutions are used as a cavity disinfectant, an etch-and-rinse bonding system should be preferred.
机译:目的:目的是评估不同型腔消毒剂对两种不同胶粘剂体系对复合树脂牙本质粘结强度的影响。材料与方法:将200颗下颌磨牙平行于牙合面切开,暴露冠状动脉中的牙本质。 -第三。牙本质表面用防水抛光纸抛光。将标本随机分为五组,每组40颗牙齿,具体如下:第1组(对照组)-标本未经任何腔体消毒剂处理。 2--5组(实验组)-牙本质表面分别用以下腔体消毒剂处理; 2%的洗必泰溶液,0.1%的氯化苯扎氯铵消毒液,1%的洗必泰凝胶和碘化碘化钾/硫酸铜基消毒剂。然后将标本随机分为两个亚组,每个亚组包括20个牙齿,以评估不同粘结系统的效果。将牙本质粘合系统应用于牙本质表面,并完成复合物堆积。将样品在培养箱中保存24小时后,以1 mm / min的十字头速度测量剪切粘结强度。然后对样本进行统计分析。使用统计分析:采用方差分析和Tukey-HSD检验的一种方法。结果:洗必泰凝胶与对照组之间无显着差异,无论所用的粘合剂类型如何(P> 0.05 )。另一方面,用基于苯扎氯铵,碘化碘化钾/硫酸铜的消毒剂或洗必泰溶液进行预处理对自蚀刻键合系统的剪切键强度有负面影响。结论:本研究的发现表明使用基于苯扎氯铵,碘化碘化钾/硫酸铜的消毒剂或洗必泰溶液作为腔体消毒剂,应首选蚀刻和冲洗结合系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号