首页> 外文期刊>Critical Care Research and Practice >Can Diaphragm Dysfunction Be Reliably Evaluated with Pocket-Sized Ultrasound Devices in Intensive Care Unit?
【24h】

Can Diaphragm Dysfunction Be Reliably Evaluated with Pocket-Sized Ultrasound Devices in Intensive Care Unit?

机译:重症监护室中的袖珍超声设备能否可靠地评估膜片功能障碍?

获取原文
           

摘要

Background. Diaphragm dysfunction (DD) is frequently seen in critically ill patients, and ultrasound could be a useful tool to detect it and to predict extubation success or failure in mechanically ventilated patients. Besides, it would also be useful in differential diagnosis of dyspnea and respiratory failure. The aim of this study is to evaluate usefulness and accuracy of pocket-sized ultrasound devices (PSDs) in assessment of DD in intensive care unit (ICU) patients in comparison with standard ultrasound devices (SD). Methods. In this prospective observational study, we compared the performance of PSD and SD in visualization of diaphragm, detection of paradoxical movement, measurement of tidal and maximal thickness, tidal and maximal excursion, and calculation of thickening fraction (TF) of the diaphragm. We used Bland and Altman test for agreement and bias analysis and intraclass correlation analysis to evaluate interobserver variability. Results. Thirty-nine patients were included in the study. In 93% of the patients, diaphragm was visualized with PSD. There was very good agreement between the measurements of the devices, and there was no proportional bias in the measurements of tidal inspiratory and expiratory thickness, tidal TF, tidal excursion, and maximal inspiratory thickness. In interobserver reliability analysis of all measurements for both devices, ICC coefficients were higher than 0.8. Total diaphragm examination times of the devices were similar (). Conclusion. These results suggest that PSD can be useful in ICU patients for evaluating DD. But further studies are required to determine the exact place of these devices in evaluation of DD in ICU patients.
机译:背景。膜片功能障碍(DD)在重症患者中屡见不鲜,而超声检查可能是检测其并预测机械通气患者拔管成功或失败的有用工具。此外,它也可用于呼吸困难和呼吸衰竭的鉴别诊断。这项研究的目的是与标准超声设备(SD)相比,评估袖珍型超声设备(PSD)在重症监护病房(ICU)患者DD评估中的实用性和准确性。方法。在这项前瞻性观察研究中,我们比较了PSD和SD在隔膜的可视化,矛盾运动的检测,潮汐和最大厚度的测量,潮汐和最大偏移以及隔膜的增稠率(TF)的计算方面的性能。我们使用Bland和Altman检验进行一致性和偏倚分析以及类内相关分析,以评估观察者间的变异性。结果。该研究包括39名患者。在93%的患者中,通过PSD可以看到隔膜。在设备的测量之间有非常好的一致性,并且在潮气和呼气厚度,潮气TF,潮气偏移和最大吸气厚度的测量中没有比例偏差。在两种设备的所有测量的观察者间可靠性分析中,ICC系数高于0.8。设备的总隔膜检查时间相似()。结论。这些结果表明,PSD在ICU患者中可用于评估DD。但是需要进一步的研究来确定这些设备在ICU患者DD评估中的确切位置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号