首页> 外文期刊>Coluna/Columna >APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING
【24h】

APPLICABILITY OF THE COBB ANGLE MEASUREMENT IN IDIOPATHIC SCOLIOSIS USING SCANNED IMAGING

机译:倾斜成像在特发性脊柱侧凸中测量Cobb角的适用性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objectives: To compare the measurement of the Cobb angle on printed radiographs and on scanned radiographs viewed through the software "PixViewer". Methods: Preoperative radiographs of 23 patients were evaluated on printed films and through the software "PixViewer". The same evaluator, a spine surgeon, chose the proximal and distal limiting vertebrae of the main curve on printed radiographs, without identification of patients, and measured the Cobb angle based on these parameters. The same parameters and measurements were applied to scanned radiographs. The measurements were compared, as well as the choice of limiting vertebrae. Results: The average variation of the Cobb angle between methods was 1.48 ?± 1.73?°. The intraclass correlation coefficient (ICC) was 0.99, demonstrating excellent reproducibility. Conclusion: The Cobb method can be used to evaluate scoliosis through the "PixViewer" tool with the same reliability as the classic method on printed radiographs.
机译:目的:比较通过软件“ PixViewer”查看的印刷X射线照片和扫描的X射线照片的Cobb角的测量结果。方法:通过印刷胶片和“ PixViewer”软件对23例患者的术前X光片进行评估。同一位评估者(脊柱外科医生)在打印的X射线照片上选择了主曲线的近端和远端限制椎骨,而没有识别出患者,并根据这些参数测量了Cobb角。将相同的参数和测量值应用于扫描的射线照片。比较了测量结果以及限制椎骨的选择。结果:两种方法之间Cobb角的平均变化为1.48°±1.73°。组内相关系数(ICC)为0.99,具有极好的可重复性。结论:Cobb方法可通过“ PixViewer”工具评估脊柱侧弯,其可靠性与印刷X射线照片上的经典方法相同。