首页> 外文期刊>CoDAS >Spilled volum, oxygen saturation, and heart rate during feeding of preterm newborns: comparison between two alternative feeding methods
【24h】

Spilled volum, oxygen saturation, and heart rate during feeding of preterm newborns: comparison between two alternative feeding methods

机译:早产儿喂养期间溢出的体积,血氧饱和度和心率:两种替代喂养方法之间的比较

获取原文
           

摘要

Purpose To compare the use of syringe and finger feeding to feed preterm newborns considering amount of milk offered, amount of milk spilled, variation of oxygen saturation, and heart rate. Methods Quasi-experimental study with 30 preterm newborns. Thirteen infants were females and 17 were males. The mean gestational age at birth and during evaluation (corrected age) was 33 4/7 ?± 4/7 and 36 ?± 4/7, respectively. Newbornsa?? mean birthweight and mean weight when evaluated was 1,800 ?± 140 and 1,972 ?± 88 grams. We assessed one feeding session using a syringe and another feeding session using the finger feeding technique. Both techniques were used in the same infant, so that the preterm newborns were controls for themselves. A portable pulse oximeter was used to check the variation of oxygen saturation and heart rate. A gauze pad was placed under the infantsa?? chin to absorb the spilled milk. The statistical tests used were: ANOVA, paired Studenta??s t test, Tukey Multiple Comparison test, and Pearson Correlation Coefficient. The level of significance was set at 5%. Results We found a difference between the techniques in terms of both amount of milk offered and amount of milk spilled. These amounts were larger when the syringe was used. Heart rate was different at two specific times: before/during and before/after feeding for both techniques. However, the values were within normal limits. Oxygen saturation values were also different, showing higher values after syringe feeding. Conclusions Finger feeding proved to cause less spillage, whereas the variations of oxygen saturation and heart rate were within normal limits.
机译:目的比较使用注射器和手指喂食喂养早产新生儿的情况,其中要考虑所提供的牛奶量,溢出的牛奶量,氧饱和度的变化和心率。方法对30例早产儿进行准实验研究。十三名婴儿是女性,而十七名是男性。出生时和评估中的平均胎龄(校正年龄)分别为33 4/7±4/7和36±4/7。新生儿?平均出生体重和评估时的平均体重分别为1,800±140克和1,972±±88克。我们评估了使用注射器的一次喂养时间和使用手指喂养技术的另一次喂养时间。两种技术均用于同一婴儿,因此早产儿是其自身的对照。使用便携式脉搏血氧仪检查氧饱和度和心率的变化。将纱布垫放在婴儿脚下?下巴吸收溢出的牛奶。使用的统计检验为:ANOVA,成对的Studenta t检验,Tukey多重比较检验和Pearson相关系数。显着性水平设定为5%。结果我们发现,在提供的牛奶量和溢出的牛奶量方面,这些技术之间存在差异。当使用注射器时,这些量更大。两种技术在两个特定时间的心率有所不同:两种技术的进食前后/进食前后。但是,该值在正常范围内。氧饱和度值也不同,在进样注射器后显示较高的值。结论事实证明,以手指喂养可以减少溢出,而氧饱和度和心率的变化在正常范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号