Purpose: To investigate the feasibility of a new method involving the use of the Verion image-guided system in preventing cyclorotation during femtosecond laser-assisted cataract surgery (FLACS). Patients: Our preliminary data included details of 24 consecutive patients. All patients underwent cataract surgery at Universal Eye Center, Zhong-Li, Taiwan, between December 2016 and January 2017. Methods: We developed a technique to use the Verion image-guided system in FLACS and evaluated whether this new technique is compatible with Femto LDV Z8. The Verion image-guided system was used to prevent misalignments. The only additional step in this technique is using a marking tool to place ink on the corneal limbus (at 3 and 9 o’clock positions) guided by the Verion digital marker system. Remaining procedures could be performed using the touchscreen of Femto LDV Z8 to calibrate the horizontal reference axis. Results: This study included 24 patients who underwent cataract surgery. The technique used could effectively neutralize misalignments at an average of 8.08° and 2.66° in clockwise and counterclockwise directions, respectively. Conclusion: This technique combines the advantages of iris fingerprinting technology and mobile features of Femto LDV Z8, has fewer transfer steps, improves centration of the eyes, and, most importantly, can prevent misalignments through cyclotorsion or docking procedures. Furthermore, this method can improve the accuracy of arcuate incisions and toric intraocular lens alignment in astigmatism correction.
机译:目的:研究一种使用Verion图像引导系统的新方法在飞秒激光辅助白内障手术(FLACS)期间预防环转的可行性。患者:我们的初步数据包括24位连续患者的详细信息。所有患者均于2016年12月至2017年1月之间在台湾中-环球眼科中心接受白内障手术。方法:我们开发了一种在FLACS中使用Verion图像引导系统的技术,并评估了该新技术是否与Femto LDV兼容Z8。 Verion图像引导系统用于防止未对准。该技术唯一的附加步骤是使用标记工具,在Verion数字标记系统的引导下,将墨水放置在角膜缘(3点和9点钟位置)上。剩余的过程可以使用Femto LDV Z8的触摸屏执行,以校准水平参考轴。结果:这项研究包括24例接受白内障手术的患者。所使用的技术可以有效地抵消分别在顺时针和逆时针方向上平均偏差为8.08°和2.66°的偏差。结论:该技术结合了虹膜指纹识别技术的优点和Femto LDV Z8的移动功能,具有更少的转移步骤,改善了眼睛的对中,并且最重要的是,可以通过环扭或对接程序防止未对准。此外,该方法可以提高散光矫正中弧形切口和复曲面人工晶状体对准的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号