Accuracy of corneal trephination depth using the Moria single-use adjustable depth vacuum trephine system

机译:使用Moria一次性可调深度真空镜面系统精确测量角膜镜面深度

获取原文
           

摘要

Background: The Moria single-use adjustable depth trephine is a device that allows a goal trephination depth to be set prior to the surgical procedure.Methods: Eleven fresh human cadaveric eyes were trephined using 8.0 mm Moria single-use adjustable vacuum trephines. Prior to trephination, the average corneal pachymetry in the peripheral 7–10 mm range was obtained using anterior segment optical coherence tomography. The trephination depth was set to 80% of that value. Light microscopy was used to image anteroposterior cross-sections of each corneal specimen. Digital protractor software was used to evaluate the trephination angle, depth, and length. All adequately processed specimens were included in the analysis. In addition, trephination angle data from a previous publication by Moshirfar et al were used as a comparison with those of this study.Results: Trephination analysis of depth compared with pachymetry revealed a mean of 83.7%±6.53% (95% confidence interval 79.8–87.6). Maximum and minimum trephined depths were 95.35% and 71.3%, respectively. Trephination depth compared with angular corneal thickness yielded a mean of 66.2%±4.79% (95% confidence interval 63.0–69.4). Maximum and minimum depths were 73.7% and 59.7%, respectively. Analysis of trephination angle yielded a mean of 130.2±3.57 degrees (95% confidence interval 127.8–132.61). Maximum and minimum angles were 135.5 degrees and 126 degrees, respectively. The standard deviation of the trephination angle of the Moria trephine was found to be significantly less than that of Hessburg-Barron and Hanna trephines calculated in the previous study.Conclusion: The Moria adjustable vacuum trephine is an accurate method of trephination when a specific depth is desired. Further investigation is needed to determine the relevance of this in relation to deep anterior lamellar keratoplasty.
机译:背景:Moria一次性可调深度金盏花是一种可以在手术前设定目标目标深度的装置。方法:使用8.0 mm Moria一次性可调真空金盏花对11只新鲜的人尸体眼进行纺纱。在进行透皮镜检查之前,使用前段光学相干断层扫描可获取7-10 mm范围内的平均角膜测厚法。脱色深度设置为该值的80%。使用光学显微镜对每个角膜标本的前后横截面成像。使用数字量角器软件评估对位角,深度和长度。分析中包括所有经过充分处理的标本。此外,使用了Moshirfar等人先前出版物中的对位角数据与本研究的结果进行了比较。结果:对深度与厚度分析法进行的对位深度分析显示平均值为83.7%±6.53%(95%置信区间79.8– 87.6)。最大和最小的深度分别为95.35%和71.3%。相较于角膜角膜厚度,化深度的平均值为66.2%±4.79%(95%置信区间63.0-69.4)。最大和最小深度分别为73.7%和59.7%。对eph角的分析得出平均值为130.2±3.57度(95%置信区间127.8–132.61)。最大和最小角度分别为135.5度和126度。发现Moria trephine的对ination角标准偏差明显小于先前研究中计算出的Hessburg-Barron和Hanna trephnes的结论。想要的。需要进一步的研究来确定其与深层前板角膜移植术的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号