首页> 外文期刊>Clinical ophthalmology >Deposit buildup on prosthetic eyes and implications for conjunctival inflammation and mucoid discharge
【24h】

Deposit buildup on prosthetic eyes and implications for conjunctival inflammation and mucoid discharge

机译:假眼上的沉积物积聚以及对结膜发炎和粘液排出的影响

获取原文
           

摘要

Background: The aim of this study was to investigate deposit buildup on prosthetic eyes and the implications for conjunctival inflammation and discharge.Methods: Forty-three prosthetic eye wearers participated in the study. Twenty-three had their prostheses polished normally before being worn continuously for 2 weeks. After this time, surface deposits were stained, photographed, and graded. The prostheses were then repolished to optical quality contact lens standard and worn for a further 2 weeks, when the deposits were again stained, photographed, and graded. Two participants had deposits on their prostheses stained, photographed, and graded on nine occasions at decreasing intervals ranging from 1 year to 1 day. Eighteen participants had the wetting angles on their prostheses measured with a goniometer before and after cleaning, after polishing normally, after polishing to optical quality contact lens standard, and after 10 minutes of wearing their optical quality contact lens polished prostheses. Concordance correlation, multiple regression, and paired t-tests were used for the statistical analysis.Results: More surface deposits accumulated on prostheses polished normally than on those polished to an optical quality contact lens standard after 2 weeks of wear. The interpalpebral zone of most prostheses (observed without magnification) appeared to be clear of deposits. Removal of deposits significantly decreased surface wettability, but wettability returned after 10 minutes of wear. Optical quality contact lens polishing produced more wettable surfaces and a slower rate of deposit accumulation than normal polishing.Conclusion: We recommend that an optical quality contact lens standard be the minimum standard of finish for prosthetic eyes. This standard may assist the smooth action of the lids over the interpalpebral zone of the prosthesis and the cleansing action of tears. The presence of deposits in the retropalpebral zone may improve the lubricating properties of socket fluids which, in turn, may result in less frictional irritation of the conjunctiva and less mucoid discharge.
机译:背景:本研究的目的是研究假眼上的沉积物及其对结膜炎症和分泌物的影响。方法:43名假眼佩戴者参加了该研究。 23个假体在连续佩戴2周之前正常打磨。在这段时间之后,对表面沉积物进行染色,照相和分级。然后将假体重新修整至符合光学质量的隐形眼镜标准,并再次佩戴2周,然后再次对沉积物进行染色,照相和分级。两名参与者的假肢上有沉积物被染色,照相和定级9次,间隔从1年到1天不等。 18名参与者在清洁前后,正常抛光后,抛光至光学质量隐形眼镜标准后以及佩戴光学质量隐形眼镜抛光假体10分钟后,用测角仪测量其假体的润湿角。结果:与正常光学质量的隐形眼镜标准品相比,经过2周的磨光后,正常抛光的假体上积累的表面沉积物多于统计学上的一致性。大多数假体的pal间区(未放大观察)似乎没有沉积物。去除沉积物会显着降低表面润湿性,但在磨损10分钟后润湿性又恢复了。与普通抛光相比,光学品质的隐形眼镜抛光可产生更多的可润湿表面,并且沉积物的沉积速率较慢。结论:我们建议将光学品质的隐形眼镜标准作为修复眼睛的最低标准。该标准可帮助假体睑间区域上的盖子平滑作用和泪液清洁作用。后睑区沉积物的存在可以改善承窝液体的润滑性能,进而可以减少对结膜的摩擦刺激并减少粘液排出。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号