Purpose: To investigate the effect of low-addition soft contact lenses (CLs) with decentered optical design on the progression of myopia in children in a pilot study.Subjects and methods: Twenty-four Japanese children age 10–16 years with baseline myopia of –0.75 to –3.50 D sphere and ≤1.00 D cylinder were studied. The new CLs were designed to have a nasal decentration with the optical center centered on the line of sight, and with progressive-addition power of +0.5 D peripherally. Monofocal soft CLs were used as controls. A pair of new CLs or control CLs was randomly assigned to the children, and they wore the lenses for 12 months during the first phase. Then, the type of CLs was changed, ie, a crossover design, and the children were observed for another 12 months during the second phase. The end points were changes in axial length and refractive error (spherical equivalent) under cycloplegia.Results: The change of axial length in the new-CL and control-CL groups was not different between 12 months and baseline, the change of axial length between 12 months and 1 month in the new-CL group (0.09±0.08 mm) was significantly smaller (47%) than that in the control-CL group (0.17±0.08 mm, P<0.05). During the same period, the change of refractive error in the new-CL group was not significantly different from that in the control group. Neither the change in axial length nor refractive error in the new-CL group was significantly different from those in the control-CL group in the second phase.Conclusion: This pilot study suggests that low-addition soft CLs with decentered optical design can reduce the degree of axial elongation in myopic children after an initial transient phase of CL wear. The reduction of the progression of myopia by low-addition soft CLs warrants further investigations.
机译:目的:在一项先导研究中,研究偏心光学设计的低附加软接触镜(CLs)对儿童近视发展的影响。研究对象和方法:二十四名年龄在10至16岁的日本儿童,其基线近视为研究了–0.75至–3.50 D球体和≤1.00D的圆柱体。新的CL被设计成具有偏心的位置,其光学中心位于视线的中心,并且在外围具有+0.5 D的渐进屈光力。将单焦点软CL用作对照。将一对新的CL或对照CL随机分配给孩子,他们在第一阶段戴了12个月的镜片。然后,更改CL的类型,即进行交叉设计,并在第二阶段中观察儿童12个月。结果:睫状肌麻痹下的轴向长度和屈光不正(球面等效)的变化。结果:new-CL组和对照组的轴向长度变化在12个月和基线之间无差异,而在- new-CL组的12个月和1个月(0.09±0.08 mm)显着小于对照组(0.17±0.08 mm,P <0.05)(47%)。在同一时期,new-CL组的屈光不正变化与对照组无显着差异。在第二阶段,new-CL组的轴向长度变化和屈光不正与对照组相比均无显着差异。结论:这项初步研究表明,偏心光学设计的低屈光性软CL可以减少CL磨损的初始瞬态阶段后,近视儿童的轴向伸长程度。低添加软性CL可以减少近视的进展,值得进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号