NON-RADIOMETRIC IMMUNOASSAYS [FLUOROIMMUNOASSAY (FIA) AND FLUOROMETRIC ENZYME IMMUNOASSAY (FEIA)] WITH RADIOIMMUNOASSAY (RIA) FOR EVALUATION OF ADRENAL FUNCTION IN NORMAL AND HYPERCORTISOLEMIC DOGS

机译:非放射性免疫分析[氟尿免疫分析(FIA)和荧光酶联免疫分析(FEIA)与放射性免疫分析(RIA)评估正常和高脂溶性狗的肾上腺功能

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Non-radiometric immunoassays offer many advantages over radiometric assays, such as higher stability of kit compounds and absence of potential hazardous effects for users and environment. The comparison of cortisol measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in adrenal function evaluation of normal (n=50) and hypercortisolemic dogs (n=12) was proposed. Serum concentrations of cortisol were measured in basal conditions and 8 hours after dexamethasone (DEX) suppression (0.01mg/kg/IV). All our reference values were based on the 5th and 95th percentile. The values for basal cortisol of healthy dogs were 0.20 to 2.35mg/d for FIA, 0.30 to 5.39mg/d for FEIA, and 0.65 to 4.64mg/d for RIA. After DEX suppression the values were 0.87mg/d, 0.30mg/d and 0.80mg/d for FIA, FEIA and RIA, respectively. In hypercortisolemic dogs, the values of cortisol (mean ± SD) in basal and post-DEX conditions were 2.71 + 0.41mg/d and 1.73 + 1.15mg/d for FIA, 7.05 + 2.85mg/d and 4.93 + 2.26mg/d for FEIA, and 4.80 + 1.43mg/d and 3.52 + 1.08mg/d for RIA. Statistically significant differences (p0.05) between the normal and the hypercortisolemic groups (Kruskal-Wallis test) were observed in the three methods, and between basal and post-DEX values (Wilcoxon test) using RIA and FEIA methods but not with FIA. Cortisol determinations by FEIA and RIA methods at DEX suppression test showed 100% of sensitivity and specificity for the diagnosis of hyperadrenocorticism in dogs. The results demonstrate that serum cortisol concentrations measurements by FEIA is a suitable alternative to the traditional RIA method for adrenal function evaluation in dogs.
机译:非放射免疫测定比放射测定具有许多优势,例如试剂盒化合物的稳定性更高,并且对使用者和环境没有潜在的危险影响。提出了通过荧光免疫测定(FIA)和荧光酶联免疫测定(FEIA)与放射免疫测定(RIA)对正常(n = 50)和肾上腺皮质功能亢进犬(n = 12)的肾上腺功能评估的皮质醇测量结果的比较。在基础条件下和地塞米松(DEX)抑制(0.01mg / kg / IV)后8小时测量血清皮质醇浓度。我们所有的参考值均基于第5个百分点和第95个百分点。健康狗的基础皮质醇值对于FIA为0.20至2.35mg / d,对于FEIA为0.30至5.39mg / d,对于RIA为0.65至4.64mg / d。抑制DEX后,FIA,FEIA和RIA的值分别为<0.87mg / d,<0.30mg / d和<0.80mg / d。在皮质功能亢进的狗中,基础和DEX后条件下的皮质醇(平均值±SD)值分别为FIA为2.71 + 0.41mg / d和1.73 + 1.15mg / d,7.05 + 2.85mg / d和4.93 + 2.26mg / d FEIA为4.80 + 1.43mg / d,RIA为3.52 + 1.08mg / d。在三种方法中,正常组和高皮质醇组(Kruskal-Wallis检验)之间以及在使用RIA和FEIA方法但未使用FIA的基础值和DEX后值(Wilcoxon检验)之间观察到统计学上的显着差异(p <0.05)。在DEX抑制试验中通过FEIA和RIA方法测定的皮质醇显示出100%的敏感性和特异性对犬高肾上腺皮质激素的诊断。结果表明,通过FEIA进行血清皮质醇浓度测量可替代传统RIA方法评估犬的肾上腺功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号