首页> 外文期刊>Chemical and Process Engineering Research >Analysis of Effect of Heat-Setting Temperatures on Crimp Parameters in Polypropylene Single-Fibres via Favimat-Robot
【24h】

Analysis of Effect of Heat-Setting Temperatures on Crimp Parameters in Polypropylene Single-Fibres via Favimat-Robot

机译:Favimat-Robot分析热定型温度对聚丙烯单纤维压接参数的影响

获取原文
           

摘要

The study on the effects of heat-setting temperature on crimp parameters of Polypropylene (PP) single-fibres was initiated by a non-woven manufacturing industry. The study is therefore important as it is addresses the real need raised by the industry to have a better comprehension of effects of heat-setting temperatures in order to optimize and develop a superior end-product. The exploratory research was conducted on non-conventional single-fibre tester Favimat-Robot (Technico), Germany at the Textile Physical testing Laboratory of Vakgroep Textielkunde Universiteit Gent (Ghent University), Belgium. Testing of PP single-fibres was limited to the following crimp parameters: Crimp Force, Crimp Length, Crimp Extension, Crimp Amplitude and Number of Crimps per cm. The collected data was statistically analyzed by the Analysis of Variance test ANOVA, using STATGRAPHICS Centurion XVI.II software, while chart was generated using Microsoft excel program. Major findings of this study reviled that all crimp parameters show a high variation. The study also revealed that the Number of Crimps per cm is increasing with increased temperature, while Crimp Length and Crimp Amplitude are decreasing with increased temperature. From the results it can be also concluded that neither of heat-setting temperatures had a clear effect on Crimp Force and on Crimp Extension. Two crimp parameters-Crimp Extension and Number of Crimps per cm-showed statistically significant difference. For more definite conclusions, the study recommends, in further research-experiments, to break the temperature-range into smaller segments, and to increase subject-temperature from two to five, by incorporating 125,130 and 135 o C.
机译:热定型温度对聚丙烯(PP)单纤维卷曲参数影响的研究是由非织造制造业发起的。因此,这项研究非常重要,因为它满足了业界提出的对热定型温度的影响有更好的理解以优化和开发优质最终产品的实际需求。这项探索性研究是在比利时根特Vakgroep Textielkunde大学的纺织物理测试实验室对非传统的单纤维测试仪Favimat-Robot(Technico)进行的。 PP单纤维的测试仅限于以下压接参数:压接力,压接长度,压接延伸,压接幅度和每厘米的压接数量。使用STATGRAPHICS Centurion XVI.II软件通过方差分析ANOVA对收集的数据进行统计分析,而使用Microsoft excel程序生成图表。这项研究的主要发现使所有压接参数都显示出很大的差异。研究还显示,随着温度的升高,每厘米的压接数会增加,而随着温度的升高,压接长度和压接幅度会减小。从结果还可以得出结论,两个热定型温度都不会对压接力和压接延伸产生明显影响。两个压接参数-压接扩展和每厘米的压接数-显示出统计上的显着差异。为了获得更确定的结论,该研究建议在进一步的研究实验中,通过合并125,130和135 o C,将温度范围分成较小的部分,并将受检者的体温从2升高到5。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号