Failure analysis of the boiler water-wall tube is presented in this work. In order to examine the causes of failure, various techniques including visual inspection, chemical analysis, optical microscopy, scanning electron microscopy and energy dispersive spectroscopy were carried out. Tube wall thickness measurements were performed on the ruptured tube. The fire-facing side of the tube was observed to have experienced significant wall thinning. The composition of the matrix material of the tube meets the requirements of the relevant standards. Microscopic examinations showed that the spheroidization of pearlite is not very obvious. The failure mechanism is identified as a result of the significant localized wall thinning of the boiler water-wall tube due to oxidation.
机译:这项工作介绍了锅炉水冷壁管的故障分析。为了检查故障原因,已进行了各种技术,包括视觉检查,化学分析,光学显微镜,扫描电子显微镜和能量色散光谱。在破裂的试管上进行试管壁厚测量。观察到管子的火面发生了明显的壁变薄。管的基体材料的组成符合相关标准的要求。显微镜检查表明珠光体的球化不是很明显。识别出故障机理是由于锅炉水冷壁管由于氧化而明显局部变薄的结果。