摘要

BACKGROUND: Diaphragmatic evaluation is crucial in clinical practice, and no studies have reported the intra- and interobserver reproducibilities of the radiographic method to evaluate diaphragmatic mobility.OBJECTIVE: To analyze the reliability of radiographic measurement as a method for assessing the mobility of the left and right hemidiaphragms. METHOD: Forty-two patients, who were waiting for cholecystectomy surgery, were evaluated relative to the following parameters: physical examination, pulmonary function and radiographic evaluation. The measure of mobility of each hemidiaphragm was randomly determined by two physical therapists at two different times. The intra- and interobserver reproducibilities of the measurements were determined by the intraclass correlation coefficient (ICC[2,1]) and the 95% confidence interval (CI). The Bland-Altman plot was also used. The level of significance was 5%. RESULTS: In the analysis of intra-observer reproducibility in radiographic evaluations of the left and right hemidiaphragms, ICC[2,1] indicated a "very high correlation" for both observer A (ICC[2,1] = 0.99, p 0.001 and ICC[2,1] = 0.97, p 0.001, respectively) and observer B (ICC[2,1] = 0.99, p 0.001 and ICC[2,1] = 0.99 p 0.001, respectively). In the analysis of interobserver reproducibility, the ICC[2,1] indicated a "very high correlation" for the 1st and 2nd radiographic evaluations of the right hemidiaphragm (ICC[2,1] = 0.98 and ICC[2,1] = 0,99, respectively, p 0.001) and left hemidiaphragm (ICC[2,1] = 0.98 and ICC[2,1] = 0.99, respectively, p 0.001). CONCLUSION: The intra and interobserver tests of the radiographic measure of mobility of the left and right hemidiaphragms showed high reliability.
机译:背景:膜片评估在临床实践中至关重要,尚无研究报道放射线照相法评估diaphragm肌活动度的观察者内和观察者间的可重复性。目的:分析放射线照相法作为评估左,右活动度的方法的可靠性。右he肌。方法:对等待胆囊切除术的42例患者进行了以下参数评估:体格检查,肺功能和放射学评估。由两名物理治疗师在两个不同的时间随机确定每个隔膜的活动性。观察者之间和观察者之间的可重复性由组内相关系数(ICC [2,1])和95%置信区间(CI)确定。还使用了Bland-Altman图。显着性水平为5%。结果:在对左右侧ph片进行放射线照相评估时观察者内可重复性的分析中,ICC [2,1]对两个观察者A均显示“非常高的相关性”(ICC [2,1] = 0.99,p <0.001和ICC [2,1] = 0.97,p <0.001,分别)和观察者B(ICC [2,1] = 0.99,p <0.001和ICC [2,1] = 0.99,p <0.001)。在观察者之间的可重复性分析中,ICC [2,1]表示右上ph肌的第1和第2射线照相评估具有“非常高的相关性”(ICC [2,1] = 0.98和ICC [2,1] = 0分别为,99,p <0.001)和左半ph(ICC [2,1] = 0.98,ICC [2,1] = 0.99,p <0.001)。结论:内和观察者间检查的左右侧he活动性的放射学测量显示出高度的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号