...
首页> 外文期刊>Brazilian Dental Journal >Effect of ridge lap surface treatment and thermocycling on microtensile bond strength of acrylic teeth to denture base resins
【24h】

Effect of ridge lap surface treatment and thermocycling on microtensile bond strength of acrylic teeth to denture base resins

机译:脊搭接表面处理和热循环对丙烯酸牙与义齿基础树脂的微拉伸粘合强度的影响

获取原文
           

摘要

This study evaluated the effect of denture base polymer type (heat- and microwave-polymerized), ridge lap surface treatment (with and without methyl methacrylate-MMA etching) and thermocycling on the microtensile bond strength (μTBS) of Biotone acrylic teeth. Flat-ground, ridge-lap surface of posterior artificial teeth were bonded to cylinders of each denture base resin, resulting in the following groups (n=6): G1a - Clássico/with MMA etching; G1b - Clássico/without MMA etching; G2a - OndaCryl/with MMA etching; G2b - OndaCryl/without MMA etching. Rectangular bar specimens with a cross-sectional area of 1 mm2 were prepared. Half of the bars in each group were thermocycled (5,000 cycles between 4oC and 60oC). μTBS testing was performed in an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by three-way ANOVA (α=0.05). There was no statisticaly significant difference (p>0.05) for the factors (resin, surface treatment,and thermocycling) or their interactions. The mean μTBS values (MPa) and standard deviations were as follows: Thermocycling - G1a: 41.00 (14.00); G1b: 31.00 (17.00); G2a: 50.00 (27.00); G2b: 40.00 (18.00); No thermocycling - G1a: 37.00 (14.00); G1b: 43.00 (25.00); G2a: 43.00 (14.00); G2b: 40.00 (27.00). The μTBS of Biotone artificial teeth to the denture base acrylic resins was not influenced by the polymer type, surface treatment or thermocycling.
机译:这项研究评估了义齿基础聚合物类型(热聚合和微波聚合),脊搭接表面处理(有或没有甲基丙烯酸甲酯-MMA蚀刻)和热循环对Biotone丙烯酸牙微拉伸强度(μTBS)的影响。将后人造牙的平坦地面,锯齿搭接表面粘合到每种义齿基础树脂的圆柱体上,得到以下组(n = 6):G1a-Clássico/ MMA蚀刻; G1b-Clássico/无MMA蚀刻; G2a-OndaCryl /具有MMA蚀刻功能; G2b-OndaCryl /无MMA蚀刻。制备横截面积为1 mm2的矩形钢筋样品。每组中一半的试条是热循环的(4oC和60oC之间的5,000个循环)。在通用测试机中以0.5 mm / min的十字头速度执行μTBS测试。数据通过三因素方差分析(α= 0.05)进行统计分析。这些因素(树脂,表面处理和热循环)或其相互作用没有统计学上的显着差异(p> 0.05)。平均TBS值(MPa)和标准偏差如下:热循环-G1a:41.00(14.00); G1b:31.00(17.00); G2a:50.00(27.00); G2b:40.00(18.00);无热循环-G1a:37.00(14.00); G1b:43.00(25.00); G2a:43.00(14.00); G2b:40.00(27.00)。 Biotone人造牙对义齿基丙烯酸树脂的μTBS不受聚合物类型,表面处理或热循环的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号