Use of the VITEK 2 system to identify and test the antifungal susceptibility of clinically relevant yeast species

机译:使用VITEK 2系统鉴定和测试临床相关酵母菌种的抗真菌药敏性

获取原文
获取外文期刊封面目录资料

摘要

Eleven quality control isolates (Candida albicans ATCC 64548, C. tropicalis ATCC 200956, C. glabrata ATCC 90030, C. lusitaniae ATCC 200951, C. parapsilosis ATCC 22019, C. krusei ATCC 6258, C. dubliniensis ATCC 6330, Saccharomyces cerevisiae ATCC 9763, Cryptococcus neoformans ATCC 90012, C. gattii FIOCRUZ-CPF 60, and Trichosporon mucoides ATCC 204094) and 32 bloodstream isolates, including C. albicans, C. tropicalis, C. parapsilosis, C. glabrata, C. krusei, C. guilliermondii, C. pelliculosa (Pichia anomala), C. haemulonii, C. lusitaniae, and C. kefyr were identified at the species level by the VITEK 2 system. A set of clinical isolates (32 total) were used as challenge strains to evaluate the ability of the VITEK 2 system to determine the antifungal susceptibility of yeasts compared with the CLSI and EUCAST BMD reference standards. The VITEK 2 system correctly identified 100% of the challenge strains. The identification of yeast species and the evaluation of their susceptibility profiles were performed in an automated manner by the VITEK 2 system after approximately 15 h of growth for most species of Candida. The VITEK 2 system ensures that each test is performed in a standardized manner and provides quantitative MIC results that are reproducible and accurate when compared with the BMD reference methods. This system was able to determine the MICs of amphotericin B, flucytosine, voriconazole, and fluconazole in 15 h or less for the most common clinically relevant Candida species. In addition, the VITEK 2 system could reliably identify resistance to flucytosine, voriconazole, and fluconazole and exhibits excellent quantitative and qualitative agreement with the CLSI or EUCAST broth microdilution reference methods.
机译:十一种质量控制分离株(白色念珠菌ATCC 64548,热带念珠菌ATCC 200956,光滑念珠菌ATCC 90030,卢西坦念珠菌ATCC 200951,副盘念珠菌ATCC 22019,克鲁斯杆菌ATCC 6258,杜氏梭菌ATCC 6330,啤酒酵母ATCC 9763 ,新隐球菌ATCC 90012,加氏梭状芽孢杆菌FIOCRUZ-CPF 60和粘液毛孢曲霉(ATCC 204094)和32种血流分离株,包括白色念珠菌,热带梭菌,副寄生梭菌,glasata glabrata,克鲁氏梭菌,guilleermondii,通过VITEK 2系统在物种水平上鉴定了C. pelliculosa(Pichia anomala),C。haemulonii,C。lusitaniae和C. kefyr。与CLSI和EUCAST BMD参考标准相比,将一组临床分离株(共32个)用作挑战菌株,以评估VITEK 2系统确定酵母抗真菌敏感性的能力。 VITEK 2系统正确识别了100%的挑战菌株。大多数酵母菌生长约15小时后,通过VITEK 2系统以自动化方式进行酵母菌种的鉴定及其敏感性分析。 VITEK 2系统可确保以标准化方式执行每个测试,并提供定量的MIC结果,与BMD参考方法相比,该结果可重复且准确。对于最常见的临床相关念珠菌,该系统能够在15小时或更短时间内确定两性霉素B,氟胞嘧啶,伏立康唑和氟康唑的MIC。此外,VITEK 2系统可以可靠地识别对氟胞嘧啶,伏立康唑和氟康唑的抗性,并且与CLSI或EUCAST肉汤微量稀释参考方法显示出极好的定量和定性一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号