...
首页> 外文期刊>BMC Musculoskeletal Disorders >The effects of the Mulligan Sustained Natural Apophyseal Glide (SNAG) mobilisation in the lumbar flexion range of asymptomatic subjects as measured by the Zebris CMS20 3-D motion analysis system
【24h】

The effects of the Mulligan Sustained Natural Apophyseal Glide (SNAG) mobilisation in the lumbar flexion range of asymptomatic subjects as measured by the Zebris CMS20 3-D motion analysis system

机译:用Zebris CMS20 3-D运动分析系统测量,Mulligan持续自然A肌滑行(SNAG)动员在无症状受试者的腰部屈曲范围内的效果

获取原文
           

摘要

Background Mulligan's mobilisation techniques are thought to increase the range of movement (ROM) in patients with low back pain. The primary aim of this study was to investigate the application of the Mulligan's Sustained Natural Apophyseal Glide (SNAG) technique on lumbar flexion ROM. The secondary aim was to measure the intra- and inter-day reliability of lumbar ROM employing the same procedure. Methods 49 asymptomatic volunteers participated in this double-blinded study. Subjects were randomly assigned to receive either SNAG mobilisation (n = 25), or a sham mobilisation (n = 24). The SNAG technique was applied at the L3and L4 spinal levels with active flexion in sitting by an experienced manual therapist. Three sets of 10 repetitions at each of the two spinal levels were performed. The sham mobilisation was similar to the SNAG but did not apply the appropriate direction or force. Lumbar ROM was measured by a three dimensional electronic goniometer (Zebris CMS20), before and after each technique. For the reliability, five measurements in two different days (one week apart) were performed in 20 healthy subjects. Results When both interventions were compared, independent t tests yielded no statistically significant results in ROM between groups (p = 0.673). Furthermore no significant within group differences were observed: SNAG (p = 0.842), sham (p = 0.169). Intra- and inter-day reliability of flexion measurements was high (ICC1,1 > 0.82, SEM Conclusion While the Zebris proved to be a reliable device for measuring lumbar flexion ROM, SNAG mobilisation did not demonstrate significant differences in flexion ROM when compared to sham mobilisation. Trial registration Current Controlled Trials NCT00678093.
机译:背景技术Mulligan的动员技术被认为可以增加下腰痛患者的运动范围(ROM)。这项研究的主要目的是研究Mulligan的可持续天然骨phy滑翔(SNAG)技术在腰屈ROM上的应用。第二个目的是使用相同的方法来测量腰间ROM的日间和日间可靠性。方法49名无症状志愿者参加了这项双盲研究。随机分配受试者接受SNAG动员(n = 25)或假动员(n = 24)。 SNAG技术应用于L 3 和L 4 脊柱水平,由经验丰富的手动治疗师主动弯曲。在两个脊髓水平中的每一个水平上进行三组,每组10次重复。伪装动员类似于SNAG,但未施加适当的指示或力量。在每种技术之前和之后,通过三维电子测角仪(Zebris CMS20)测量腰椎ROM。为了提高可靠性,在20位健康受试者的两天内(相隔一周)进行了五次测量。结果当将两种干预措施进行比较时,独立的t检验在两组之间的ROM方面无统计学意义(p = 0.673)。此外,未观察到组内显着差异:SNAG(p = 0.842),假(p = 0.169)。 SEM的日间和日间可靠性很高(ICC 1,1

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号