...
首页> 外文期刊>Brazilian Oral Research >Assessment of enamel demineralization using conventional, digital, and digitized radiography
【24h】

Assessment of enamel demineralization using conventional, digital, and digitized radiography

机译:使用常规,数字和数字化射线照相术评估牙釉质脱矿质

获取原文
   

获取外文期刊封面封底 >>

       

摘要

This experimental research aimed at evaluating the accuracy of enamel demineralization detection using conventional, digital, and digitized radiographs, as well as to compare radiographs and logarithmically contrast-enhanced subtraction images. Enamel subsurface demineralization was induced on one of the approximal surfaces of 49 sound third molars. Standardized radiographs of the teeth were taken prior to and after the demineralization phase with three digital systems - CygnusRay MPS?, DenOptix? and DIGORA? - and InSight? film. Three radiologists interpreted the pairs of conventional, digital, and digitized radiographs in two different occasions. Logarithmically contrast-enhanced subtraction images were examined by a fourth radiologist only once. Radiographic diagnosis was validated by cross-sectional microhardness profiling in the test areas of the approximal surfaces. Accuracy was estimated by Receiver Operating Characteristic (ROC) analysis. Chi-square test, at a significance level of 5%, was used to compare the areas under the ROC curves (Az) calculated for the different imaging modalities. Concerning the radiographs, the DenOptix? system (Az = 0.91) and conventional radiographs (Az = 0.90) presented the highest accuracy values compared with the other three radiographic modalities. However, logarithmically contrast-enhanced subtraction images (Az = 0.98) were significantly more accurate than conventional, digital, and digitized radiographs (p = 0.0000). It can be concluded that the DenOptix? system and conventional radiographs provide better performance for diagnosing enamel subsurface demineralization. Logarithmic subtraction significantly improves radiographic detection.
机译:这项实验研究旨在评估使用常规,数字和数字化射线照片的牙釉质脱矿质检测的准确性,以及比较射线照片和对数对比度增强的减影图像。在49个健全的第三磨牙的近似表面之一上诱导了搪瓷表面的脱矿质作用。在脱盐阶段之前和之后,使用三种数字系统CygnusRay MPS?,DenOptix?对牙齿进行了标准化的X线照片。和DIGORA? -和InSight?电影。三位放射科医生在两种不同的情况下解释了一对传统的,数字的和数字化的射线照片。对数增强的减影图像仅由第四位放射科医生检查一次。通过在近似表面的测试区域中进行横截面显微硬度分析来验证射线照相诊断。通过接收器工作特性(ROC)分析来估计准确性。卡方检验(显着性水平为5%)用于比较针对不同成像方式计算的ROC曲线(Az)下的面积。关于射线照相,DenOptix?系统(Az = 0.91)和传统的X射线照片(Az = 0.90)与其他三种射线照相模式相比,具有最高的准确度值。但是,对数对比度增强的减影图像(Az = 0.98)比传统的,数字的和数字化的X射线照片(p = 0.0000)准确得多。可以得出结论,DenOptix?系统和常规X射线照片为诊断牙釉质地下脱矿质提供了更好的性能。对数减法显着改善了射线照相检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号