...
首页> 外文期刊>BioMedical Engineering OnLine >Investigations concerning the application of the cross-correlation method in cardiac output measurements
【24h】

Investigations concerning the application of the cross-correlation method in cardiac output measurements

机译:关于互相关法在心输出量测量中的应用的研究

获取原文
           

摘要

Background In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodilution are sensitive to many physical and biological disturbances. The unreliability of this method amounts to 20-45% and depends on the given variant of the method. Therefore some other method, more accurate and resistant to disturbances, was looked for. This paper presents a new approach to cardiac output measurements, based on cross-correlation signal analysis. The goal of investigations was to verify experimentally the application of the cross-correlation method of cardiac output measurements. Results In 99.2% of the examined cases the extreme of the cross-correlation function was easy to be estimated by numerical algorithms. In 0,8% of the remaining cases (with a plateau region adjacent to the maximum point) numerical detection of the extreme was inaccurate. The typical unreliability of the investigated method amounted o 5.1% (9.8% in the worst case). Investigations performed on a physical model revealed that the unreliability of cardiac output measurements by means of the cross-correlation method is 3–5 times better than in the case of thermodilution. Conclusions The performed investigations and theoretical analysis have shown, that the cross-correlation method may be applied in cardiac output measurements. This kind of measurements seems to be more accurate and disturbance-resistant than clinically applied thermodilution.
机译:背景技术尽管进行了许多无创检查,但心输出量测量的“黄金临床标准”仍然是通过Swan-Ganz导管进行的有创肺动脉导管插入术以及热稀释法用于估计血流的方法。通过热稀释获得的结果对许多物理和生物干扰都很敏感。该方法的不可靠性总计为20-45%,并取决于该方法的给定变体。因此,寻找其他更准确和抗干扰的方法。本文提出了一种基于互相关信号分析的心输出量测量新方法。研究的目的是通过实验验证心输出量测量的互相关方法的应用。结果在99.2%的检查病例中,互相关函数的极值很容易通过数值算法进行估计。在0.8%的其余情况下(高原区域与最大点相邻),极端情况的数值检测不准确。研究方法的典型不可靠性为5.1%(最坏情况为9.8%)。对物理模型进行的研究表明,通过互相关方法进行的心输出量测量的不可靠性比热稀释法提高了3-5倍。结论进行的研究和理论分析表明,互相关法可用于心输出量的测量。这种测量似乎比临床应用的热稀释法更准确,更抗干扰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号