首页> 外文期刊>BioMedical Engineering OnLine >Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
【24h】

Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring

机译:经声发射监测的疲劳试验下牙髓治疗的牙种植体支撑假体的生物力学相互作用

获取原文
           

摘要

Background This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. Methods Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an abutment were used for this investigation and their corresponding mechanical resistances in conformity with the ISO 14801 standard were evaluated. The endodontically treated TISP samples were constructed containing TIS and RS implants splinted to the second premolar with fatigue tests performed by applying occlusal force onto the premolar simulating the bending moment effect. The numbers of accumulated AE signals in the fatigue tests and failure modes for the sample were recorded to evaluate the mechanical resistance. Result The maximum load in the static test for RS (3-piece) implant (797N) was significantly higher than that for the TIS (2-piece) implant (559N). Large deformations were found at abutment screws in both RS and TIS implants. Although the numbers of accumulated AE signals for the TIS implant (72511) were higher than those for the RS implant (437), statistical non-significant differences were found between TIS and RS implants. No obvious damage was noted in endodontically treated TISP samples using RS implants but two of the corresponding TIS implants fractured in the abutment screws. Conclusions Splints with RS (3-piece) implant prosthesis produce better mechanical responses than the TIS (2-piece) implant when connected to an endodontically treated tooth restored with a post core and crown.
机译:背景技术这项研究调查了在使用声发射(AE)技术监测的动态循环载荷下,经牙髓治疗的牙种植体支撑假体(TISP)与种植体系统变化之间的生物力学相互作用。方法采用锥度整体旋入式(TIS; 2件式植入物)和与基台连接的固定螺钉(RS; 3件式植入物)的宏观结构植入物进行研究,其相应的机械阻力符合ISO标准评估了14801标准。构造经牙髓治疗的TISP样品,其中包含TIS和RS植入物,这些植入物夹在第二前磨牙上,并通过在前磨牙上施加咬合力模拟弯矩效应进行疲劳测试。记录样品在疲劳测试和失效模式下累积的AE信号的数量,以评估机械阻力。结果RS(三件式)植入物(797N)的静态测试中的最大负载显着高于TIS(两件式)植入物(559N)的最大负载。 RS和TIS种植体的基台螺钉处都发现较大的变形。尽管TIS植入物(72511)的累积AE信号数量高于RS植入物(437)的累积AE信号数量,但在TIS和RS植入物之间发现统计学上无显着差异。在使用RS种植体进行牙髓治疗的TISP样品中未发现明显的损伤,但相应的两个TIS种植体在基台螺钉中断裂。结论RS(3片式)假体的夹板与TIS(2片式)假体连接到经牙髓和牙冠修复的牙髓治疗牙齿时,产生的机械响应优于TIS(2片)假体。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号