首页> 外文期刊>Breast Cancer Research >AutoDensity: an automated method to measure mammographic breast density that predicts breast cancer risk and screening outcomes
【24h】

AutoDensity: an automated method to measure mammographic breast density that predicts breast cancer risk and screening outcomes

机译:AutoDensity:一种自动测量乳​​房X线照片的乳房密度的方法,可预测乳腺癌风险和筛查结果

获取原文
           

摘要

IntroductionWhile Cumulus – a semi-automated method for measuring breast density – is utilised extensively in research, it is labour-intensive and unsuitable for screening programmes that require an efficient and valid measure on which to base screening recommendations. We develop an automated method to measure breast density (AutoDensity) and compare it to Cumulus in terms of association with breast cancer risk and breast cancer screening outcomes.MethodsAutoDensity automatically identifies the breast area in the mammogram and classifies breast density in a similar way to Cumulus, through a fast, stand-alone Windows or Linux program. Our sample comprised 985 women with screen-detected cancers, 367 women with interval cancers and 4,975 controls (women who did not have cancer), sampled from first and subsequent screening rounds of a film mammography screening programme. To test the validity of AutoDensity, we compared the effect estimates using AutoDensity with those using Cumulus from logistic regression models that tested the association between breast density and breast cancer risk, risk of small and large screen-detected cancers and interval cancers, and screening programme sensitivity (the proportion of cancers that are screen-detected). As a secondary analysis, we report on correlation between AutoDensity and Cumulus measures.ResultsAutoDensity performed similarly to Cumulus in all associations tested. For example, using AutoDensity, the odds ratios for women in the highest decile of breast density compared to women in the lowest quintile for invasive breast cancer, interval cancers, large and small screen-detected cancers were 3.2 (95% CI 2.5 to 4.1), 4.7 (95% CI 3.0 to 7.4), 6.4 (95% CI 3.7 to 11.1) and 2.2 (95% CI 1.6 to 3.0) respectively. For Cumulus the corresponding odds ratios were: 2.4 (95% CI 1.9 to 3.1), 4.1 (95% CI 2.6 to 6.3), 6.6 (95% CI 3.7 to 11.7) and 1.3 (95% CI 0.9 to 1.8). Correlation between Cumulus and AutoDensity measures was 0.63 (P < 0.001).ConclusionsBased on the similarity of the effect estimates for AutoDensity and Cumulus in models of breast density and breast cancer risk and screening outcomes, we conclude that AutoDensity is a valid automated method for measuring breast density from digitised film mammograms.
机译:引言虽然积算法是一种半自动化的测量乳房密度的方法,但在研究中得到了广泛的应用,但是它是劳动密集型的,因此不适合需要有效,有效的筛查建议基础的筛查计划。我们开发了一种自动测量乳​​房密度的方法(AutoDensity),并将其与Cumulus进行比较,将其与乳腺癌风险和乳腺癌筛查结果相关联.MethodsAutoDensity可自动识别乳房X线照片中的乳房区域并以类似于Cumulus的方式对乳房密度进行分类通过快速的独立Windows或Linux程序。我们的样本包括985名患有筛查癌症的妇女,367名患有间歇性癌症的妇女和4,975名对照(未患癌症的妇女),这些都是从X线乳房X线照片筛查程序的第一轮和后续筛查中抽取的。为了测试AutoDensity的有效性,我们将使用AutoDensity的效果估计值与使用Logistic回归模型的Cumulus的效果估计值进行了比较,该模型测试了乳房密度与乳腺癌风险,经大小筛查的癌症和间歇性癌症的风险以及筛查程序之间的关联敏感性(被筛查的癌症比例)。作为辅助分析,我们报告了自动密度和累积量度之间的相关性。结果在所有测试的关联中,自动密度的执行方式与累积量相似。例如,使用AutoDensity,在乳腺密度最高的十分位数中的女性与五分位数最低的女性中,浸润性乳腺癌,间歇性癌症,筛查的大小型癌症的比值比为3.2(95%CI 2.5至4.1)分别为4.7(95%CI为3.0至7.4),6.4(95%CI为3.7至11.1)和2.2(95%CI为1.6至3.0)。对于积云,相应的优势比为:2.4(95%CI 1.9至3.1),4.1(95%CI 2.6至6.3),6.6(95%CI 3.7至11.7)和1.3(95%CI 0.9至1.8)。积算与AutoDensity量度之间的相关性为0.63(P <0.001)。结论基于乳房密度,乳腺癌风险和筛查结果模型中AutoDensity和Cumulus的效果估计值相似,我们得出结论,AutoDensity是一种有效的自动化测量方法数字化胶片X线照片显示的乳房密度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号