This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.
机译:这项研究通过剂量学测试展示了X射线辐照器的特性,从而证实了小动物和细胞在放射生物学实验过程中所暴露的实际剂量率。我们评估了在辐照过程中放置​​动物或细胞的位置的线性,一致性,可重复性和剂量分布。此外,我们评估了X射线管(电压和管工作电流),辐射测量(泄漏辐射)和安全装置的性能。辐照器的默认设置为160 kV和25 mA。测试表明剂量率是线性随时间变化的(R2 = 1),并且在两次读数之间的长(恒定)和短(可重复性)间隔内保持稳定。动物笼内的平均剂量率为1.27±0.06 Gy / min,均匀光束为95.40%(高于制造商保证的最低阈值)。细胞板内的平均剂量率为0.92±0.19 Gy / min。剂量率与管电压和电流的关系分别呈现二次和线性关系。在评估辐射器安全装置的过程中没有观察到机械故障,辐射测量得出的最大环境当量剂量率为0.26 mSv / h,这使它免于国际原子能机构的辐射防护要求。辐照器的特性使我们能够进行放射生物学实验,并协助甚至替代传统的细胞和小型动物辐照治疗设备(例如线性加速器),尤其是在早期研究阶段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号