Background New surgical techniques are developed to enable a quicker, easier and safer surgery with reduced risk of complications and shortened time needed for recovery. A resorbable device, a self-locking loop, was designed for surgical ligation. The objective of this pilot study was to investigate the feasibility of ligating the spermatic cord with the device, its biocompatibility and long-term resorption in dogs. Results The device was made of a block co-polymer (glycolide and trimethylene carbonate), manufactured by injection moulding and consisted of a flexible band running through a case with a locking mechanism. Ten devices were tested for ligation of the spermatic cords in five dogs admitted for routine neutering. The dogs were monitored by physical examination and ultrasonography of the site of ligation, area of spermatic cord and medial iliac lymph nodes regularly until no hyperechoic remnants of the device or acoustic shadowing or local tissue reactions were observed. Haemostasis of the spermatic cords was achieved with the devices. On ultrasonography the devices were seen as hyperechoic structures for 2?months after neutering causing acoustic shadowing for 1?month. The dogs were monitored for 3 – 5?months after surgery. Gradual decrease in echogenicity and final disappearance of the hyperechoic structures suggested resorption. Macroscopic and histological post mortem examinations were performed in one dog at 3?months after surgery. Post mortem examination showed a tissue reaction of a suture granuloma that was restricted in extent at site of the device. Conclusions The results of this pilot study suggest biocompatibility and indicate that ligation of the spermatic cord is feasible with the device.
机译:背景技术开发出新的外科手术技术以实现更快,更容易和更安全的手术,同时降低并发症的风险并缩短恢复所需的时间。一种可吸收的装置,一个自锁环,被设计用于手术结扎。这项初步研究的目的是研究将精索与该装置连接的可行性,其生物相容性和在犬中的长期吸收。结果该装置由嵌段共聚物(乙交酯和碳酸三亚甲基酯)制成,通过注塑成型制造,由一条柔性带子组成,该柔性带子穿过带有锁定机构的壳体。测试了十个装置在五只接受常规绝育手术的狗中的精索结扎。定期通过体格检查和超声检查结扎部位,精索区域和media内侧淋巴结,对犬进行监测,直到未观察到该装置的高回声残留或听觉阴影或局部组织反应。用该装置实现了精索的止血。在超声检查中,该器械在绝育后2个月内被视为高回声结构,导致声影持续1个月。手术后对狗进行3 – 5个月的监测。回声的逐渐降低和高回声结构的最终消失提示了吸收。在手术后3个月,对一只狗进行宏观和组织学验尸检查。验尸显示,缝合肉芽肿的组织反应在装置部位受到限制。结论这项初步研究的结果表明了其生物相容性,并表明该装置可连接精索。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号