首页> 外文期刊>BMC Pulmonary Medicine >Global lung function initiative 2012 reference values for spirometry in Asian Americans
【24h】

Global lung function initiative 2012 reference values for spirometry in Asian Americans

机译:全球肺功能倡议2012年亚裔美国人的肺活量测定参考值

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Spirometry reference values specifically designed for Asian Americans are currently unavailable. The performance of Global Lung Function Initiative 2012 (GLI-2012) equations on assessing spirometry in Asian Americans has not been evaluated. This study aimed to assess the fitness of relevant GLI-2012 equations for spirometry in Asian Americans. Asian subjects who never smoked and had qualified spirometry data were extracted from the National Health and Nutrition Examination Survey (NHANES) 2011–2012. Z-scores of forced expiratory volume in 1?s (FEV1), forced vital capacity (FVC), and FEV1/FVC were separately constructed with GLI-2012 equations for North East (NE) Asians, South East (SE) Asians, and individuals of mixed ethnic origin (Mixed). In addition, Proportions of subjects with observed spirometry data below the lower limit of normal (LLN) were also evaluated on each GLI-2012 equation of interest. This study included 567 subjects (250 men and 317 women) aged 6–79?years. Spirometry z-scores (z-FEV1, z-FVC, and z-FEV1/FVC) based on GLI-2012 Mixed equations had mean values close to zero (??0.278 to ??0.057) and standard deviations close to one (1.001 to 1.128); additionally, 6.0% (95% confidence interval (CI) 3.1–8.9%) and 6.4% (95% CI 3.7–9.1%) of subjects were with observed data below LLN for FEV1/FVC in men and women, respectively. In contrast, for NE Asian equations, all mean values of z-FEV1 and z-FVC were smaller than ??0.5; for SE Asian equations, mean values of z-FEV1/FVC were significantly smaller than zero in men (??0.333) and women (??0.440). GLI-2012 equations for individuals of mixed ethnic origin adequately fitted spirometry data in this sample of Asian Americans. Future studies with larger sample sizes are needed to confirm these findings.
机译:目前尚没有专门为亚裔美国人设计的肺活量测定参考值。尚未评估2012年全球肺功能计划(GLI-2012)等式在评估亚裔美国人的肺活量方面的表现。这项研究旨在评估亚裔美国人中有关GLI-2012肺活量测定方程的适用性。从未吸烟且具有合格肺活量测定数据的亚洲受试者摘自2011-2012年国家健康与营养检查调查(NHANES)。分别使用GLI-2012方程分别针对东北亚(NE)亚洲人,东南亚(SE)亚洲人和澳大利亚人使用GLI-2012方程构造了1秒内的呼气量(FEV1),强制肺活量(FVC)和FEV1 / FVC的Z值。混合种族的个人(混合)。此外,还对每个感兴趣的GLI-2012方程评估了观察到的肺活量数据低于正常下限(LLN)的受试者比例。这项研究纳入了6岁至79岁的567名受试者(250名男性和317名女性)。基于GLI-2012混合方程的肺活量测验z分数(z-FEV1,z-FVC和z-FEV1 / FVC)的平均值接近于零(?0.278至?0.057),标准差接近于一(1.001)至1.128);此外,分别有6.0%(95%置信区间(CI)3.1–8.9%)和6.4%(95%CI 3.7–9.1%)受试者的FEV1 / FVC低于LLN。相反,对于NE Asian方程,z-FEV1和z-FVC的所有平均值均小于0.5。对于SE Asian方程,男性(?0.333)和女性(?0.440)的z-FEV1 / FVC平均值均明显小于零。 GLI-2012方程适用于混血族裔个体,该肺活量测定数据完全适合该亚裔美国人样本。需要进行更大样本量的未来研究以证实这些发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号